FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

252793002: Intraoperative neurophysiological monitoring (regime/therapy)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
376520011 Intraoperative neurophysiological monitoring en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1472062015 Intraoperative neurophysiological monitoring (regime/therapy) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


9 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Intraoperative neurophysiological monitoring Is a Neuroelectrophysiology test true Inferred relationship Some
Intraoperative neurophysiological monitoring Has intent Diagnostic intent (qualifier value) false Inferred relationship Some 2
Intraoperative neurophysiological monitoring Procedure site Neuromuscular junction (cell structure) false Inferred relationship Some
Intraoperative neurophysiological monitoring Method Investigation - action false Inferred relationship Some
Intraoperative neurophysiological monitoring Is a Neurological monitoring regime (regime/therapy) true Inferred relationship Some
Intraoperative neurophysiological monitoring Method Evaluation - action false Inferred relationship Some 1
Intraoperative neurophysiological monitoring Has focus Neurological finding false Inferred relationship Some
Intraoperative neurophysiological monitoring Procedure site Structure of nervous system (body structure) false Inferred relationship Some 1
Intraoperative neurophysiological monitoring Method Monitoring - action false Inferred relationship Some 3
Intraoperative neurophysiological monitoring Procedure site - Direct (attribute) Structure of nervous system (body structure) false Inferred relationship Some 1
Intraoperative neurophysiological monitoring Method Evaluation - action false Inferred relationship Some 1
Intraoperative neurophysiological monitoring Procedure site - Direct (attribute) Structure of nervous system (body structure) true Inferred relationship Some 1
Intraoperative neurophysiological monitoring Method Monitoring - action true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Intraoperative sensory nerve stimulation Is a True Intraoperative neurophysiological monitoring Inferred relationship Some
Intraoperative motor nerve stimulation Is a True Intraoperative neurophysiological monitoring Inferred relationship Some
Electroencephalogram for monitoring at surgery Is a True Intraoperative neurophysiological monitoring Inferred relationship Some

This concept is not in any reference sets

Back to Start