Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
277127010 | Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
562090018 | Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Is a | Revision to closed reduction of fracture and internal fixation with screw(s) (procedure) | false | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Is a | Closed reduction of fracture of hip | true | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Access | Closed approach | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site | Structure of neck of femur | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site | Bone structure | false | Inferred relationship | Some | 6 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Using | Bone screw | false | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Revision status | Revision - value | false | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Fixation - action | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Fixation - action | false | Inferred relationship | Some | 6 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Access | Open approach | false | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site | Bone structure | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Is a | Operation on trunk | false | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct device | Bone screw | false | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Using | Orthopedic internal fixation system | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site | Bone structure | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Indirect (attribute) | Bone structure | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Indirect (attribute) | Bone structure | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct device | Orthopedic internal fixation system | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Indirect (attribute) | Bone structure | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Indirect (attribute) | Bone structure | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Indirect (attribute) | Bone structure | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Indirect (attribute) | Bone structure | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Indirect (attribute) | Bone structure | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Indirect (attribute) | Bone structure | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Direct (attribute) | Bone structure | false | Inferred relationship | Some | 4 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Direct (attribute) | Bone structure | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Using device (attribute) | Bone screw | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Direct (attribute) | Structure of neck of femur | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Using device (attribute) | Orthopedic internal fixation system | false | Inferred relationship | Some | 4 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Using device (attribute) | Orthopedic internal fixation system | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Reduction - action | false | Inferred relationship | Some | 4 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 3 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 4 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Access | Closed approach | false | Inferred relationship | Some | 4 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Access | Closed approach | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Is a | Fixation of hip | false | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Is a | Revision closed reduction and internal fixation of fracture | true | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Is a | Closed reduction of fracture of femur with internal fixation | true | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Closed reduction - action (qualifier value) | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Fixation - action | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Direct (attribute) | Bone structure of proximal femur (body structure) | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Direct (attribute) | Bone structure of proximal femur (body structure) | false | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Using device (attribute) | Orthopedic internal fixation system | false | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Direct (attribute) | Bone structure of proximal femur (body structure) | true | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Procedure site - Direct (attribute) | Bone structure of proximal femur (body structure) | true | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Fixation - action | true | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Using device (attribute) | Orthopedic internal fixation system | true | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | true | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Revision status | Revision - value | true | Inferred relationship | Some | 1 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Method | Closed reduction - action (qualifier value) | true | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Direct morphology | Fracture | true | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Revision status | Revision - value | true | Inferred relationship | Some | 2 | |
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Is a | Refixation | false | Inferred relationship | Some | ||
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device | Is a | Operative procedure on hip (procedure) | true | Inferred relationship | Some |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Reference Sets
Description inactivation indicator reference set