FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

179107004: Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
277127010 Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
562090018 Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Is a Revision to closed reduction of fracture and internal fixation with screw(s) (procedure) false Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Is a Closed reduction of fracture of hip true Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Access Closed approach false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site Structure of neck of femur false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site Bone structure false Inferred relationship Some 6
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Using Bone screw false Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Revision status Revision - value false Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 6
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Access Open approach false Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site Bone structure false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Is a Operation on trunk false Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct device Bone screw false Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Using Orthopedic internal fixation system false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site Bone structure false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct device Orthopedic internal fixation system false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Bone structure false Inferred relationship Some 4
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Bone structure false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Using device (attribute) Bone screw false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Structure of neck of femur false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Using device (attribute) Orthopedic internal fixation system false Inferred relationship Some 4
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Using device (attribute) Orthopedic internal fixation system false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Reduction - action false Inferred relationship Some 4
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 3
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 4
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Access Closed approach false Inferred relationship Some 4
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Access Closed approach false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Is a Fixation of hip false Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Is a Revision closed reduction and internal fixation of fracture true Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Is a Closed reduction of fracture of femur with internal fixation true Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Closed reduction - action (qualifier value) false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Bone structure of proximal femur (body structure) false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Bone structure of proximal femur (body structure) false Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Using device (attribute) Orthopedic internal fixation system false Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Bone structure of proximal femur (body structure) true Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Procedure site - Direct (attribute) Bone structure of proximal femur (body structure) true Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Fixation - action true Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Using device (attribute) Orthopedic internal fixation system true Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture true Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Revision status Revision - value true Inferred relationship Some 1
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Method Closed reduction - action (qualifier value) true Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Direct morphology Fracture true Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Revision status Revision - value true Inferred relationship Some 2
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Is a Refixation false Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Is a Operative procedure on hip (procedure) true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Description inactivation indicator reference set

GB English

US English

Back to Start