FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

1334047006: Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 01-Jun 2024. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
5351840017 Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
5352289016 Fluoroscopy guided percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries with contrast en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
5352290013 Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Is a Angiography of bilateral carotid arteries (procedure) true Inferred relationship Some
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Access Percutaneous approach true Inferred relationship Some 1
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Method Occlusion - action true Inferred relationship Some 1
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Structure of right internal carotid artery true Inferred relationship Some 1
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Using device (attribute) Balloon dilatation catheter (physical object) true Inferred relationship Some 1
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Access Percutaneous approach true Inferred relationship Some 2
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Method Occlusion - action true Inferred relationship Some 2
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Structure of left internal carotid artery true Inferred relationship Some 2
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Using device (attribute) Balloon dilatation catheter (physical object) true Inferred relationship Some 2
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 3
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Structure of right internal carotid artery true Inferred relationship Some 3
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 3
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Using substance (attribute) Contrast media (substance) true Inferred relationship Some 3
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 4
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Structure of left internal carotid artery true Inferred relationship Some 4
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 4
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Using substance (attribute) Contrast media (substance) true Inferred relationship Some 4
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Is a Percutaneous transluminal balloon test occlusion of left internal carotid artery using fluoroscopic guidance with contrast (procedure) true Inferred relationship Some
Percutaneous transluminal balloon test occlusion of bilateral internal carotid arteries using fluoroscopic guidance with contrast (procedure) Is a Percutaneous transluminal balloon test occlusion of right internal carotid artery using fluoroscopic guidance with contrast (procedure) true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start