FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.12  |  FHIR Version n/a  User: [n/a]

716317007: Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2017. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4010905018 Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
4010906017 Fluoroscopy guided measurement of intravascular pressure with contrast en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4010907014 Measurement of intravascular pressure using fluoroscopic guidance with contrast en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Is a Measurement true Inferred relationship Some
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Is a Fluoroscopic guidance true Inferred relationship Some
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Is a Fluoroscopic angiography with contrast (procedure) true Inferred relationship Some
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Blood vessel structure (body structure) true Inferred relationship Some 2
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Blood vessel structure (body structure) false Inferred relationship Some 3
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Component Blood pressure false Inferred relationship Some 2
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Method Measurement - action false Inferred relationship Some 2
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 3
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Has intent Guidance intent (qualifier value) false Inferred relationship Some 3
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Method Measurement - action true Inferred relationship Some 1
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Procedure site - Direct (attribute) Blood vessel structure (body structure) true Inferred relationship Some 1
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 2
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Using substance (attribute) Contrast media (substance) true Inferred relationship Some 2
Measurement of intravascular pressure using fluoroscopic guidance with contrast (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start