Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 30-Jun 2022. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2880442014 | Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2882054014 | Removal of cardiac monitoring implant using fluoroscopic guidance | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
5070118015 | Removal of electrocardiography loop recorder using fluoroscopic guidance | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Is a | Removal of implant | false | Inferred relationship | Some | ||
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Is a | Fluoroscopic guidance | true | Inferred relationship | Some | ||
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Has intent | Guidance intent (qualifier value) | false | Inferred relationship | Some | 1 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Method | Surgical removal - action | false | Inferred relationship | Some | 2 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | false | Inferred relationship | Some | 1 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Direct device | Cardiac implant | false | Inferred relationship | Some | 2 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Has intent | Guidance intent (qualifier value) | true | Inferred relationship | Some | 1 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | true | Inferred relationship | Some | 1 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Method | Surgical removal - action | true | Inferred relationship | Some | 2 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Direct device | Cardiac implant | false | Inferred relationship | Some | 2 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Is a | Removal of electrocardiography loop recorder (procedure) | false | Inferred relationship | Some | ||
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Direct device | Electrocardiographic monitor and recorder | true | Inferred relationship | Some | 2 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Is a | Removal of electronic heart device | true | Inferred relationship | Some | ||
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Method | Surgical removal - action | true | Inferred relationship | Some | 3 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Procedure site - Indirect (attribute) | Heart structure | true | Inferred relationship | Some | 3 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Direct device | Biomedical equipment | true | Inferred relationship | Some | 3 | |
Removal of cardiac monitoring implant using fluoroscopic guidance (procedure) | Direct device | Electrocardiographic monitor and recorder | true | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets