FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

1208351009: Lobectomy of thyroid gland using robotic assistance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 28-Feb 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4963780013 Lobectomy of thyroid gland using robotic assistance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
4963781012 Lobectomy of thyroid gland using robotic assistance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4963782017 Hemithyroidectomy using robotic assistance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Lobectomy of thyroid gland using robotic assistance (procedure) Is a Lobectomy of thyroid gland true Inferred relationship Some
Lobectomy of thyroid gland using robotic assistance (procedure) Is a Robotic assisted surgery true Inferred relationship Some
Lobectomy of thyroid gland using robotic assistance (procedure) Method Excision - action (qualifier value) true Inferred relationship Some 1
Lobectomy of thyroid gland using robotic assistance (procedure) Procedure site - Direct (attribute) Structure of lobe of thyroid gland true Inferred relationship Some 1
Lobectomy of thyroid gland using robotic assistance (procedure) Using device (attribute) Robot false Inferred relationship Some 1
Lobectomy of thyroid gland using robotic assistance (procedure) Using access device (attribute) Endoscope false Inferred relationship Some 1
Lobectomy of thyroid gland using robotic assistance (procedure) Is a Endoscopy of thyroid true Inferred relationship Some
Lobectomy of thyroid gland using robotic assistance (procedure) Method Inspection - action true Inferred relationship Some 2
Lobectomy of thyroid gland using robotic assistance (procedure) Procedure site - Direct (attribute) Structure of lobe of thyroid gland true Inferred relationship Some 2
Lobectomy of thyroid gland using robotic assistance (procedure) Using device (attribute) Endoscope true Inferred relationship Some 2
Lobectomy of thyroid gland using robotic assistance (procedure) Using device (attribute) Robotic arm true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start