FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

252596007: Alternate binaural loudness balance test (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
376226016 Alternate binaural loudness balance test en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
376227013 ABLB - Alternate binaural loudness balance test en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
376228015 Loudness recruitment test en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
376229011 Fowler's test en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
643246016 Alternate binaural loudness balance test (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Alternate binaural loudness balance test Is a Behavioral diagnostic hearing test true Inferred relationship Some
Alternate binaural loudness balance test Method Investigation - action false Inferred relationship Some
Alternate binaural loudness balance test Has intent Diagnostic intent (qualifier value) false Inferred relationship Some 2
Alternate binaural loudness balance test Procedure site Ear structure false Inferred relationship Some 1
Alternate binaural loudness balance test Procedure site Upper respiratory tract structure false Inferred relationship Some 1
Alternate binaural loudness balance test Method Evaluation - action false Inferred relationship Some 1
Alternate binaural loudness balance test Method Evaluation - action false Inferred relationship Some 2
Alternate binaural loudness balance test Procedure site - Direct (attribute) Structure of auditory system (body structure) false Inferred relationship Some 1
Alternate binaural loudness balance test Method Testing - action false Inferred relationship Some 1
Alternate binaural loudness balance test Procedure site - Direct (attribute) Structure of auditory system (body structure) true Inferred relationship Some 1
Alternate binaural loudness balance test Method Testing - action false Inferred relationship Some 1
Alternate binaural loudness balance test Method Evaluation - action false Inferred relationship Some 1
Alternate binaural loudness balance test Procedure site - Direct (attribute) Structure of auditory system (body structure) false Inferred relationship Some 1
Alternate binaural loudness balance test Method Evaluation - action true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start