FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

764840003: Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jul 2018. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
3655260019 GSPECT of myocardium using technetium (99m-Tc) sestamibi en Synonym Active Entire term case sensitive SNOMED CT core module
3657290010 Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi (procedure) en Fully specified name Active Only initial character case insensitive SNOMED CT core module
3657291014 Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi en Synonym Active Only initial character case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi Is a Electrocardiographic monitoring true Inferred relationship Existential restriction modifier
Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi Is a Single photon emission computed tomography of heart true Inferred relationship Existential restriction modifier
Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi Is a Radionuclide imaging of myocardium using technetium (99m-Tc) sestamibi true Inferred relationship Existential restriction modifier
Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi Method Monitoring - action true Inferred relationship Existential restriction modifier 2
Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi Procedure site - Direct Heart structure true Inferred relationship Existential restriction modifier 2
Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi Using device Electrocardiographic monitor and recorder, device true Inferred relationship Existential restriction modifier 2
Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi Procedure site - Direct Myocardium structure true Inferred relationship Existential restriction modifier 1
Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi Using substance Technetium (99m-Tc) sestamibi true Inferred relationship Existential restriction modifier 1
Gated single photon emission computed tomography of myocardium using technetium (99m-Tc) sestamibi Method Single photon emission computed tomography - action true Inferred relationship Existential restriction modifier 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start