FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

70752002: Removal of spinal electronic stimulator with synchronous replacement (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
117529019 Removal of spinal electronic stimulator with synchronous replacement en Synonym Active Entire term case insensitive SNOMED CT core module
117530012 Replacement of spinal neurostimulator en Synonym Active Entire term case insensitive SNOMED CT core module
117531011 Removal of spinal neurostimulator with synchronous replacement en Synonym Active Entire term case insensitive SNOMED CT core module
810842017 Removal of spinal electronic stimulator with synchronous replacement (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Removal of spinal electronic stimulator with synchronous replacement Is a Removal of spinal neurostimulator true Inferred relationship Existential restriction modifier
Removal of spinal electronic stimulator with synchronous replacement Is a Replacement of device false Inferred relationship Existential restriction modifier
Removal of spinal electronic stimulator with synchronous replacement Method Surgical action false Inferred relationship Existential restriction modifier 2
Removal of spinal electronic stimulator with synchronous replacement Procedure site Spinal canal structure false Inferred relationship Existential restriction modifier
Removal of spinal electronic stimulator with synchronous replacement Procedure site Spinal cord tissue structure false Inferred relationship Existential restriction modifier 3
Removal of spinal electronic stimulator with synchronous replacement Method Removal - action false Inferred relationship Existential restriction modifier
Removal of spinal electronic stimulator with synchronous replacement Method Introduction - action false Inferred relationship Existential restriction modifier
Removal of spinal electronic stimulator with synchronous replacement Is a Operation on spinal cord true Inferred relationship Existential restriction modifier
Removal of spinal electronic stimulator with synchronous replacement Is a Operation on trunk false Inferred relationship Existential restriction modifier
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action false Inferred relationship Existential restriction modifier 2
Removal of spinal electronic stimulator with synchronous replacement Procedure site Structure of nervous system false Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Direct device Device false Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Is a Replacement of device true Inferred relationship Existential restriction modifier
Removal of spinal electronic stimulator with synchronous replacement Procedure site Spinal cord structure false Inferred relationship Existential restriction modifier 2
Removal of spinal electronic stimulator with synchronous replacement Direct device Device false Inferred relationship Existential restriction modifier 2
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action false Inferred relationship Existential restriction modifier 3
Removal of spinal electronic stimulator with synchronous replacement Is a Operative procedure on spinal structure false Inferred relationship Existential restriction modifier
Removal of spinal electronic stimulator with synchronous replacement Method Removal - action false Inferred relationship Existential restriction modifier 2
Removal of spinal electronic stimulator with synchronous replacement Method Stimulation - action false Inferred relationship Existential restriction modifier 5
Removal of spinal electronic stimulator with synchronous replacement Procedure site - Indirect Structure of central nervous system false Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Procedure site Structure of nervous system false Inferred relationship Existential restriction modifier 5
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action false Inferred relationship Existential restriction modifier 4
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action false Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Direct device Neurostimulator, device false Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Procedure site - Indirect Spinal cord tissue structure false Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action false Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action false Inferred relationship Existential restriction modifier 4
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action false Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action false Inferred relationship Existential restriction modifier 3
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action false Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action false Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Method Replacement - action true Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Procedure site - Indirect Spinal cord tissue structure true Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Direct device Neurostimulator, device true Inferred relationship Existential restriction modifier 1
Removal of spinal electronic stimulator with synchronous replacement Procedure site Spinal cord structure true Inferred relationship Existential restriction modifier 2
Removal of spinal electronic stimulator with synchronous replacement Method Surgical action true Inferred relationship Existential restriction modifier 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start