FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

706004007: Implantable cardiac pacemaker (physical object)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jul 2014. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
3025217018 Implantable cardiac pacemaker en Synonym Active Entire term case insensitive SNOMED CT core module
3025218011 Implantable cardiac pacemaker (physical object) en Fully specified name Active Entire term case insensitive SNOMED CT core module


7 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implantable cardiac pacemaker Is a Cardiac pacemaker, device true Inferred relationship Existential restriction modifier
Implantable cardiac pacemaker Is a Implant, device true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group
Cardiac resynchronization therapy implantable pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier
Dual chamber demand implantable cardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier
Dual chamber rate responsive implantable cardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier
Intracardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier
Single chamber fixed rate and/or demand implantable cardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier
Single chamber rate responsive implantable cardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier
Removal of implantable cardiac pacemaker Direct device True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 1
Leadless implantable cardiac pacemaker Is a True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier
Malfunction of biventricular cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 2
Malfunction of biventricular cardiac pacemaker battery Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 2
Protrusion of cardiac device Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 2
Stimulation of muscle pocket due to and after implantation of cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 4
Infected pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 2
Infection of biventricular cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 2
Cross-talk in dual chamber cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 1
Stimulation of phrenic nerve due to and after implantation of cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 4
Infection of pacemaker pulse generator site Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 3
Pacemaker electrode infection Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 2
Erosion of pacemaker pocket due to and following implantation of cardiac pacemaker Associated with True Implantable cardiac pacemaker Inferred relationship Existential restriction modifier 4

This concept is not in any reference sets

Back to Start