FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

704115002: Revision of cardiac pacemaker electrode using fluoroscopic guidance (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2015. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
3011896011 Fluoroscopy guided revision of cardiac pacemaker electrode en Synonym Active Entire term case insensitive SNOMED CT core module
3012160013 Revision of cardiac pacemaker electrode using fluoroscopic guidance en Synonym Active Entire term case insensitive SNOMED CT core module
3012478012 Revision of cardiac pacemaker electrode using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Revision of cardiac pacemaker electrode using fluoroscopic guidance Is a Operation on heart true Inferred relationship Existential restriction modifier
Revision of cardiac pacemaker electrode using fluoroscopic guidance Is a Cardiac fluoroscopy true Inferred relationship Existential restriction modifier
Revision of cardiac pacemaker electrode using fluoroscopic guidance Is a Revision true Inferred relationship Existential restriction modifier
Revision of cardiac pacemaker electrode using fluoroscopic guidance Is a Cardiac pacemaker procedure false Inferred relationship Existential restriction modifier
Revision of cardiac pacemaker electrode using fluoroscopic guidance Is a Fluoroscopic guidance false Inferred relationship Existential restriction modifier
Revision of cardiac pacemaker electrode using fluoroscopic guidance Revision status Revision - value true Inferred relationship Existential restriction modifier 2
Revision of cardiac pacemaker electrode using fluoroscopic guidance Method Surgical action true Inferred relationship Existential restriction modifier 2
Revision of cardiac pacemaker electrode using fluoroscopic guidance Direct device Cardiac pacemaker electrode true Inferred relationship Existential restriction modifier 2
Revision of cardiac pacemaker electrode using fluoroscopic guidance Procedure site - Indirect Heart structure true Inferred relationship Existential restriction modifier 2
Revision of cardiac pacemaker electrode using fluoroscopic guidance Method Fluoroscopic imaging - action true Inferred relationship Existential restriction modifier 3
Revision of cardiac pacemaker electrode using fluoroscopic guidance Has intent Guidance intent true Inferred relationship Existential restriction modifier 3
Revision of cardiac pacemaker electrode using fluoroscopic guidance Procedure site - Direct Heart structure true Inferred relationship Existential restriction modifier 3
Revision of cardiac pacemaker electrode using fluoroscopic guidance Is a Biomedical equipment procedure true Inferred relationship Existential restriction modifier
Revision of cardiac pacemaker electrode using fluoroscopic guidance Is a Cardiac pacemaker procedure using fluoroscopic guidance true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start