Status: retired, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2023. Module: SNOMED CT core module
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
3769361012 | Insertion of catheter into spinal canal for infusion of therapeutic substance (procedure) | en | Fully specified name | Active | Entire term case insensitive | SNOMED CT core module |
3769362017 | Insertion of catheter into spinal canal for infusion of therapeutic substance | en | Synonym | Active | Entire term case insensitive | SNOMED CT core module |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Is a | Insertion of catheter in spinal canal space, epidural, subarachnoid or subdural, for infusion of therapeutic or palliative substances | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Direct device | Appliance | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Direct device | Catheter, device | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure site | Structure of spinal cerebrospinal fluid pathway | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Method | Surgical action | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Method | Implantation - action | false | Inferred relationship | Existential restriction modifier | 2 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure site | Structure of nervous system | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure site | Body structure | false | Inferred relationship | Existential restriction modifier | 2 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Using | Catheter, device | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Method | Insertion - action | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Direct device | Catheter, device | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Direct device | Implant, device | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure device | Catheter, device | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Direct device | Catheter, device | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure site - Indirect | Structure of spinal cerebrospinal fluid pathway | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure site - Direct | Structure of spinal cerebrospinal fluid pathway | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure site | Structure of spinal cerebrospinal fluid pathway | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Method | Surgical action | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure site | Structure of spinal cerebrospinal fluid pathway | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Method | Surgical action | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure site - Indirect | Structure of spinal cerebrospinal fluid pathway | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Direct device | Catheter, device | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Method | Insertion - action | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Has intent | Palliative - procedure intent | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Method | Insertion - action | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Direct device | Catheter, device | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure site - Indirect | Spinal canal structure | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Procedure site - Indirect | Spinal canal structure | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Is a | Catheterization | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Is a | Procedure on spine | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Direct substance | Drug or medicament | false | Inferred relationship | Existential restriction modifier | 1 | |
Insertion of catheter into spinal canal for infusion of therapeutic substance | Is a | Introduction of substance by body site | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Is a | Therapeutic procedure | false | Inferred relationship | Existential restriction modifier | ||
Insertion of catheter into spinal canal for infusion of therapeutic substance | Has intent | Therapeutic intent | false | Inferred relationship | Existential restriction modifier | 2 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets