FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

55455004: Revision of pacemaker electrode leads (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
92192011 Revision of pacemaker electrode leads en Synonym Active Entire term case insensitive SNOMED CT core module
92193018 Revision of cardiac pacemaker electrodes en Synonym Active Entire term case insensitive SNOMED CT core module
92194012 Reposition of cardiac pacemaker electrodes en Synonym Active Entire term case insensitive SNOMED CT core module
793817017 Revision of pacemaker electrode leads (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Revision of pacemaker electrode leads Is a Revision of permanent cardiac pacemaker device false Inferred relationship Existential restriction modifier
Revision of pacemaker electrode leads Is a Repair of pacemaker electrodes false Inferred relationship Existential restriction modifier
Revision of pacemaker electrode leads Method Maintenance - action false Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Procedure site Cardiac structure false Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Direct device Cardiac pacemaker, device false Inferred relationship Existential restriction modifier 2
Revision of pacemaker electrode leads Method Implantation - action false Inferred relationship Existential restriction modifier 2
Revision of pacemaker electrode leads Method Surgical action false Inferred relationship Existential restriction modifier
Revision of pacemaker electrode leads Has intent Permanent false Inferred relationship Existential restriction modifier
Revision of pacemaker electrode leads Procedure site Heart structure false Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Revision status Revision - value false Inferred relationship Existential restriction modifier 2
Revision of pacemaker electrode leads Procedure site Body structure false Inferred relationship Existential restriction modifier 2
Revision of pacemaker electrode leads Method Management - action false Inferred relationship Existential restriction modifier
Revision of pacemaker electrode leads Method Insertion - action false Inferred relationship Existential restriction modifier 4
Revision of pacemaker electrode leads Method Maintenance - action false Inferred relationship Existential restriction modifier 2
Revision of pacemaker electrode leads Direct device Cardiac pacemaker, device false Inferred relationship Existential restriction modifier 3
Revision of pacemaker electrode leads Method Repair - action false Inferred relationship Existential restriction modifier 2
Revision of pacemaker electrode leads Direct device Cardiac pacemaker electrode false Inferred relationship Existential restriction modifier 5
Revision of pacemaker electrode leads Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 4
Revision of pacemaker electrode leads Procedure device Permanent cardiac pacemaker, device false Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Method Surgical action false Inferred relationship Existential restriction modifier 2
Revision of pacemaker electrode leads Method Maintenance - action false Inferred relationship Existential restriction modifier 3
Revision of pacemaker electrode leads Method Maintenance - action false Inferred relationship Existential restriction modifier 5
Revision of pacemaker electrode leads Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 3
Revision of pacemaker electrode leads Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 5
Revision of pacemaker electrode leads Method Mechanical repair - action false Inferred relationship Existential restriction modifier 3
Revision of pacemaker electrode leads Method Mechanical repair - action false Inferred relationship Existential restriction modifier 5
Revision of pacemaker electrode leads Direct device Cardiac pacemaker, device false Inferred relationship Existential restriction modifier 3
Revision of pacemaker electrode leads Direct device Cardiac pacemaker electrode false Inferred relationship Existential restriction modifier 5
Revision of pacemaker electrode leads Is a Cardiac pacemaker procedure true Inferred relationship Existential restriction modifier
Revision of pacemaker electrode leads Is a Revision true Inferred relationship Existential restriction modifier
Revision of pacemaker electrode leads Method Surgical action false Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Revision status Revision - value false Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Direct device Cardiac pacemaker lead false Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Method Surgical action true Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Direct device Cardiac pacemaker lead true Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Revision status Revision - value true Inferred relationship Existential restriction modifier 1
Revision of pacemaker electrode leads Is a Biomedical equipment procedure true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start