46645006: Replacement of electroencephalographic receiver in brain (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
77741010 Replacement of electroencephalographic receiver in brain en Synonym Active Entire term case insensitive SNOMED CT core module
77742015 Removal of electroencephalographic receiver from brain with synchronous replacement en Synonym Active Entire term case insensitive SNOMED CT core module
784017013 Replacement of electroencephalographic receiver in brain (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of electroencephalographic receiver in brain Is a Replacement of pacemaker in brain false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Is a Implantation of electroencephalographic receiver in brain false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Method Implantation - action false Inferred relationship Existential restriction modifier 2
Replacement of electroencephalographic receiver in brain Procedure site Brain tissue structure false Inferred relationship Existential restriction modifier 1
Replacement of electroencephalographic receiver in brain Direct device Neurostimulator electrode false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Method Surgical action false Inferred relationship Existential restriction modifier 1
Replacement of electroencephalographic receiver in brain Is a Replacement of device false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Method Replacement - action false Inferred relationship Existential restriction modifier 1
Replacement of electroencephalographic receiver in brain Procedure site Brain structure false Inferred relationship Existential restriction modifier 2
Replacement of electroencephalographic receiver in brain Is a Removal of device from central nervous system false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Is a Replacement of device false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Method Insertion - action false Inferred relationship Existential restriction modifier 1
Replacement of electroencephalographic receiver in brain Procedure site Brain tissue structure false Inferred relationship Existential restriction modifier 1
Replacement of electroencephalographic receiver in brain Procedure site Brain tissue structure false Inferred relationship Existential restriction modifier 2
Replacement of electroencephalographic receiver in brain Is a Replacement procedure false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Using Neurostimulator, device false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Procedure site Brain tissue structure false Inferred relationship Existential restriction modifier 1
Replacement of electroencephalographic receiver in brain Is a Removal of therapeutic device false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Is a Replacement of device false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Is a Removal of device from central nervous system false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Direct device Implant, device false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Procedure site Brain tissue structure false Inferred relationship Existential restriction modifier 2
Replacement of electroencephalographic receiver in brain Is a Replacement procedure true Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Is a Procedure on brain true Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Procedure site - Indirect Brain tissue structure false Inferred relationship Existential restriction modifier 1
Replacement of electroencephalographic receiver in brain Is a Procedure on organ false Inferred relationship Existential restriction modifier
Replacement of electroencephalographic receiver in brain Method Replacement - action true Inferred relationship Existential restriction modifier 1
Replacement of electroencephalographic receiver in brain Procedure site - Indirect Brain tissue structure true Inferred relationship Existential restriction modifier 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets