FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

46136006: Electrocardiogram with exercise test (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
76923016 Electrocardiogram with exercise test en Synonym Active Entire term case insensitive SNOMED CT core module
76926012 Exercise electrocardiogram en Synonym Active Entire term case insensitive SNOMED CT core module
783452017 Electrocardiogram with exercise test (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module
1230306013 Exercise stress ECG test en Synonym Active Only initial character case insensitive SNOMED CT core module
1230307016 Exercise ECG en Synonym Active Only initial character case insensitive SNOMED CT core module


8 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Electrocardiogram with exercise test Is a Cardiovascular stress testing true Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Is a Exercise tolerance test false Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Is a Electrocardiographic monitoring true Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Method Measurement - action false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Method Investigation - action false Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Using Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Is a Diagnostic procedure by site false Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Direct device Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Using Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier 2
Electrocardiogram with exercise test Method Monitoring - action false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Electrocardiogram with exercise test Is a Exercise tolerance test true Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Using device Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site - Direct Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site - Direct Heart structure false Inferred relationship Existential restriction modifier 2
Electrocardiogram with exercise test Using device Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier 2
Electrocardiogram with exercise test Method Monitoring - action false Inferred relationship Existential restriction modifier 2
Electrocardiogram with exercise test Method Monitoring - action true Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Using device Electrocardiographic monitor and recorder, device true Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site - Direct Heart structure true Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Method Measurement - action false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Electrocardiogram with exercise test Is a Diagnostic procedure on heart false Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test Has intent Diagnostic intent false Inferred relationship Existential restriction modifier 2

Inbound Relationships Type Active Source Characteristic Refinability Group
Ellestad protocol Is a True Electrocardiogram with exercise test Inferred relationship Existential restriction modifier
Ramp protocol Is a True Electrocardiogram with exercise test Inferred relationship Existential restriction modifier
Pepper protocol Is a True Electrocardiogram with exercise test Inferred relationship Existential restriction modifier
Electrocardiogram with maximal exercise test Is a True Electrocardiogram with exercise test Inferred relationship Existential restriction modifier
Cardiovascular stress test using bicycle ergometer Is a False Electrocardiogram with exercise test Inferred relationship Existential restriction modifier
Electrocardiogram with sub-maximal exercise test Is a True Electrocardiogram with exercise test Inferred relationship Existential restriction modifier
Masters' stress test, two-step Is a True Electrocardiogram with exercise test Inferred relationship Existential restriction modifier
Cardiovascular stress test using treadmill Is a False Electrocardiogram with exercise test Inferred relationship Existential restriction modifier
Pharmacologic and exercise stress test Is a True Electrocardiogram with exercise test Inferred relationship Existential restriction modifier
Electrocardiogram with exercise test using Bruce protocol Is a True Electrocardiogram with exercise test Inferred relationship Existential restriction modifier

This concept is not in any reference sets

Back to Start