FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

444801008: Infection associated with biventricular automatic implantable cardioverter defibrillator (disorder)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 30-Sep 2021. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
2868852012 Infection associated with biventricular automatic implantable cardioverter defibrillator (disorder) en Fully specified name Active Entire term case insensitive SNOMED CT core module
2871163016 Infection associated with biventricular automatic implantable cardioverter defibrillator en Synonym Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Infection associated with biventricular automatic implantable cardioverter defibrillator Pathological process Infectious process true Inferred relationship Existential restriction modifier 1
Infection associated with biventricular automatic implantable cardioverter defibrillator Is a Infection as complication of medical care false Inferred relationship Existential restriction modifier
Infection associated with biventricular automatic implantable cardioverter defibrillator Is a Healthcare associated infectious disease true Inferred relationship Existential restriction modifier
Infection associated with biventricular automatic implantable cardioverter defibrillator Due to Procedure false Inferred relationship Existential restriction modifier 2
Infection associated with biventricular automatic implantable cardioverter defibrillator During Hospital care true Inferred relationship Existential restriction modifier 2
Infection associated with biventricular automatic implantable cardioverter defibrillator Is a Infection following procedure true Inferred relationship Existential restriction modifier
Infection associated with biventricular automatic implantable cardioverter defibrillator Is a Infection associated with cardiac implant true Inferred relationship Existential restriction modifier
Infection associated with biventricular automatic implantable cardioverter defibrillator Associated with Implantable defibrillator, device true Inferred relationship Existential restriction modifier 4
Infection associated with biventricular automatic implantable cardioverter defibrillator After Insertion of biventricular implantable cardioverter defibrillator true Inferred relationship Existential restriction modifier 3
Infection associated with biventricular automatic implantable cardioverter defibrillator Is a Disorder of implantable defibrillator true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start