Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2010. Module: SNOMED CT core module
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2834298017 | Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | en | Fully specified name | Active | Entire term case insensitive | SNOMED CT core module |
2837510016 | Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | en | Synonym | Active | Entire term case insensitive | SNOMED CT core module |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Is a | Fixation of fracture using screws | true | Inferred relationship | Existential restriction modifier | ||
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Is a | Open reduction of fracture of femur with internal fixation | true | Inferred relationship | Existential restriction modifier | ||
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Is a | Fixation of fracture using wire | true | Inferred relationship | Existential restriction modifier | ||
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Is a | Fixation of hip | false | Inferred relationship | Existential restriction modifier | ||
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Method | Open reduction - action | true | Inferred relationship | Existential restriction modifier | 1 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Using device | Bone wire, device | true | Inferred relationship | Existential restriction modifier | 2 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Direct morphology | Fracture | true | Inferred relationship | Existential restriction modifier | 3 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Method | Fixation - action | true | Inferred relationship | Existential restriction modifier | 2 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Method | Fixation - action | true | Inferred relationship | Existential restriction modifier | 3 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Direct morphology | Fracture | true | Inferred relationship | Existential restriction modifier | 1 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Direct morphology | Fracture | true | Inferred relationship | Existential restriction modifier | 2 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Procedure site - Direct | Intertrochanteric structure of femur | true | Inferred relationship | Existential restriction modifier | 1 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Procedure site - Direct | Intertrochanteric structure of femur | true | Inferred relationship | Existential restriction modifier | 2 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Procedure site - Direct | Intertrochanteric structure of femur | true | Inferred relationship | Existential restriction modifier | 3 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Using device | Bone screw, device | true | Inferred relationship | Existential restriction modifier | 3 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | Is a | Operative procedure on hip | true | Inferred relationship | Existential restriction modifier |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets