FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

433844000: Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Oct 2021. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
2745797015 Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module
2767439014 Insertion of cardiac biventricular implantable cardioverter defibrillator (ICD) using fluoroscopic guidance en Synonym Active Only initial character case insensitive SNOMED CT core module
2767440011 Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance en Synonym Active Entire term case insensitive SNOMED CT core module
2773768011 Fluoroscopic guidance for insertion of cardiac biventricular ICD en Synonym Active Only initial character case insensitive SNOMED CT core module
703951000000113 Fluoroscopy guided insertion of cardiac biventricular ICD en Synonym Active Entire term case sensitive SNOMED CT United Kingdom Edition module
706281000000117 Cardiac biventricular ICD insertion en Synonym Active Entire term case sensitive SNOMED CT United Kingdom Edition module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Insertion of cardiac defibrillator using fluoroscopic guidance false Inferred relationship Existential restriction modifier
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Insertion - action true Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Has intent Guidance intent false Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Fluoroscopic imaging - action false Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Automatic cardiac defibrillator false Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Direct Heart structure false Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Insertion - action false Inferred relationship Existential restriction modifier 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Automatic cardiac defibrillator false Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Direct Heart structure false Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Has intent Guidance intent false Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Fluoroscopic imaging - action false Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Insertion of biventricular implantable cardioverter defibrillator true Inferred relationship Existential restriction modifier
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Insertion - action false Inferred relationship Existential restriction modifier 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Implantable defibrillator, device false Inferred relationship Existential restriction modifier 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Indirect Heart structure true Inferred relationship Existential restriction modifier 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Implantable defibrillator, device false Inferred relationship Existential restriction modifier 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Implantable defibrillator, device true Inferred relationship Existential restriction modifier 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Fluoroscopic imaging - action true Inferred relationship Existential restriction modifier 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Has intent Guidance intent true Inferred relationship Existential restriction modifier 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Implantation - action true Inferred relationship Existential restriction modifier 3
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Indirect Heart structure true Inferred relationship Existential restriction modifier 3
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Implantable defibrillator, device true Inferred relationship Existential restriction modifier 3
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Insertion using fluoroscopic guidance true Inferred relationship Existential restriction modifier
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Cardiovascular investigation true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start