FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

433031009: Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance (procedure)


    Status: retired, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2019. Module: SNOMED CT core module

    Descriptions:

    Id Description Lang Type Status Case? Module
    2747579012 Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module
    2769442010 Cardiac catheterisation with insertion of pressure wire using fluoroscopic guidance en Synonym Active Entire term case insensitive SNOMED CT core module
    2769443017 Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance en Synonym Active Entire term case insensitive SNOMED CT core module
    702621000000119 Fluoroscopy guided cardiac catheterisation with insertion of pressure wire en Synonym Active Entire term case sensitive SNOMED CT United Kingdom Edition module
    712101000000119 Fluoroscopic guidance for cardiac catheterisation with insertion of pressure wire en Synonym Active Only initial character case insensitive SNOMED CT United Kingdom Edition module


    0 descendants.

    Expanded Value Set


    Outbound Relationships Type Target Active Characteristic Refinability Group Values
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Is a Cardiac catheterization false Inferred relationship Existential restriction modifier
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Is a Insertion of cardiac pressure wire using fluoroscopic guidance false Inferred relationship Existential restriction modifier
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Direct device Intracoronary pressure guide wire false Inferred relationship Existential restriction modifier 2
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 2
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Method Insertion - action false Inferred relationship Existential restriction modifier 3
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Method Insertion - action false Inferred relationship Existential restriction modifier 2
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Method Fluoroscopic imaging - action false Inferred relationship Existential restriction modifier 1
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Direct device Vascular catheter false Inferred relationship Existential restriction modifier 3
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Has intent Guidance intent false Inferred relationship Existential restriction modifier 1
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Procedure site - Direct Heart structure false Inferred relationship Existential restriction modifier 1
    Cardiac catheterization with insertion of pressure wire using fluoroscopic guidance Procedure site - Indirect Heart structure false Inferred relationship Existential restriction modifier 3

    Inbound Relationships Type Active Source Characteristic Refinability Group

    This concept is not in any reference sets

    Back to Start