FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

43129000: Radionuclide dynamic function study with multiple probes (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
71951014 Radionuclide dynamic function study with multiple probes en Synonym Active Entire term case insensitive SNOMED CT core module
780105016 Radionuclide dynamic function study with multiple probes (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Radionuclide dynamic function study with multiple probes Is a Nuclear medicine study of function true Inferred relationship Existential restriction modifier
Radionuclide dynamic function study with multiple probes Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Radionuclide dynamic function study with multiple probes Method Radionuclide imaging - action true Inferred relationship Existential restriction modifier 1
Radionuclide dynamic function study with multiple probes Method Investigation - action false Inferred relationship Existential restriction modifier
Radionuclide dynamic function study with multiple probes Direct substance Radioactive isotope false Inferred relationship Existential restriction modifier 1
Radionuclide dynamic function study with multiple probes Method Introduction - action false Inferred relationship Existential restriction modifier 1
Radionuclide dynamic function study with multiple probes Is a Nuclear medicine imaging procedure true Inferred relationship Existential restriction modifier
Radionuclide dynamic function study with multiple probes Is a Imaging false Inferred relationship Existential restriction modifier
Radionuclide dynamic function study with multiple probes Using substance Radioactive isotope true Inferred relationship Existential restriction modifier 1
Radionuclide dynamic function study with multiple probes Method Radionuclide imaging - action false Inferred relationship Existential restriction modifier 1
Radionuclide dynamic function study with multiple probes Using substance Radioactive isotope false Inferred relationship Existential restriction modifier 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start