FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

4002008: Mechanical complication due to intrauterine contraceptive device (disorder)


    Status: retired, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2013. Module: SNOMED CT core module

    Descriptions:

    Id Description Lang Type Status Case? Module
    8670011 Mechanical complication due to intrauterine contraceptive device en Synonym Active Entire term case insensitive SNOMED CT core module
    8671010 IUD complication en Synonym Active Entire term case sensitive SNOMED CT core module
    8672015 IUCD complication en Synonym Active Entire term case sensitive SNOMED CT core module
    776585014 Mechanical complication due to intrauterine contraceptive device (disorder) en Fully specified name Active Entire term case insensitive SNOMED CT core module


    0 descendants.

    Expanded Value Set


    Outbound Relationships Type Target Active Characteristic Refinability Group Values
    Mechanical complication due to intrauterine contraceptive device Is a Mechanical complication of genitourinary device, implant AND/OR graft false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device Is a Disorder of intrauterine contraceptive device false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device Causative agent Device false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device Finding site Uterine structure false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device Temporally follows Procedure false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device Temporally follows Surgical procedure false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device Temporally follows Intrauterine contraceptive device procedure false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device Temporally follows Surgical procedure false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device Temporally follows Implantation false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device After Implantation false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device After Intrauterine contraceptive device procedure false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device After Surgical procedure false Inferred relationship Existential restriction modifier
    Mechanical complication due to intrauterine contraceptive device Associated with Surgical procedure false Inferred relationship Existential restriction modifier

    Inbound Relationships Type Active Source Characteristic Refinability Group
    Disorder associated with retained intrauterine contraceptive device Is a False Mechanical complication due to intrauterine contraceptive device Inferred relationship Existential restriction modifier
    Expulsion intrauterine contraceptive device Is a False Mechanical complication due to intrauterine contraceptive device Inferred relationship Existential restriction modifier

    This concept is not in any reference sets

    Back to Start