FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

35785002: Measurement of gamma-enolase (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jul 2004. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
59681019 Neuron-specific enolase measurement en Synonym Active Entire term case insensitive SNOMED CT core module
5136930010 Measurement of gamma-enolase (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module
5136931014 Measurement of gamma-enolase en Synonym Active Entire term case insensitive SNOMED CT core module
5136932019 NSE (neuron-specific enolase) measurement en Synonym Active Entire term case sensitive SNOMED CT core module


1 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Measurement of gamma-enolase Is a Enzyme measurement false Inferred relationship Existential restriction modifier
Measurement of gamma-enolase Has measured component Gamma-enolase false Inferred relationship Existential restriction modifier
Measurement of gamma-enolase Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Measurement of gamma-enolase Method Investigation - action false Inferred relationship Existential restriction modifier
Measurement of gamma-enolase Component Gamma-enolase true Inferred relationship Existential restriction modifier 1
Measurement of gamma-enolase Method Evaluation - action false Inferred relationship Existential restriction modifier
Measurement of gamma-enolase Method Measurement - action true Inferred relationship Existential restriction modifier 2
Measurement of gamma-enolase Is a Enolase measurement true Inferred relationship Existential restriction modifier
Measurement of gamma-enolase Is a Tumor marker measurement true Inferred relationship Existential restriction modifier
Measurement of gamma-enolase PBCL flag true PBCL flag true: report, request, level, test false Additional relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group
Measurement of gamma-enolase in serum Is a True Measurement of gamma-enolase Inferred relationship Existential restriction modifier
Gamma-enolase level above reference range Interprets True Measurement of gamma-enolase Inferred relationship Existential restriction modifier 1

This concept is not in any reference sets

Back to Start