FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

313442000: Serum prolactin measurement (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jan 2004. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
457340010 Serum prolactin level en Synonym Active Entire term case insensitive SNOMED CT core module
457341014 Serum prolactin measurement en Synonym Active Entire term case insensitive SNOMED CT core module
710209013 Serum prolactin measurement (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


8 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Serum prolactin measurement Is a Prolactin measurement true Inferred relationship Existential restriction modifier
Serum prolactin measurement Method Investigation - action false Inferred relationship Existential restriction modifier
Serum prolactin measurement Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Serum prolactin measurement Has measured component Prolactin false Inferred relationship Existential restriction modifier
Serum prolactin measurement Component Prolactin true Inferred relationship Existential restriction modifier 2
Serum prolactin measurement Method Evaluation - action false Inferred relationship Existential restriction modifier
Serum prolactin measurement Has specimen Serum specimen true Inferred relationship Existential restriction modifier 1
Serum prolactin measurement Is a Measurement of substance in specimen false Inferred relationship Existential restriction modifier
Serum prolactin measurement Method Measurement - action true Inferred relationship Existential restriction modifier 3
Serum prolactin measurement Is a Measurement of level of drug in blood false Inferred relationship Existential restriction modifier
Serum prolactin measurement Is a Measurement of level of substance in blood true Inferred relationship Existential restriction modifier
Serum prolactin measurement PBCL flag true PBCL flag true: report, request, level, test false Additional relationship Existential restriction modifier
Serum prolactin measurement PBCL flag true PBCL flag true: report, request, level, test false Additional relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group
Serum monomeric prolactin level Is a True Serum prolactin measurement Inferred relationship Existential restriction modifier
Serum prolactin isoform profile Is a True Serum prolactin measurement Inferred relationship Existential restriction modifier
120 minute serum prolactin measurement Is a True Serum prolactin measurement Inferred relationship Existential restriction modifier
60 minute serum prolactin measurement Is a True Serum prolactin measurement Inferred relationship Existential restriction modifier
30 minute serum prolactin measurement Is a True Serum prolactin measurement Inferred relationship Existential restriction modifier
150 minute serum prolactin measurement Is a True Serum prolactin measurement Inferred relationship Existential restriction modifier
90 minute serum prolactin measurement Is a True Serum prolactin measurement Inferred relationship Existential restriction modifier
Measurement of prolactin in serum specimen using polyethylene glycol recovery (procedure) Is a True Serum prolactin measurement Inferred relationship Existential restriction modifier

This concept is not in any reference sets

Back to Start