FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

303619008: Cardiac implant (physical object)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
445799018 Cardiac implant en Synonym Active Entire term case insensitive SNOMED CT core module
699825014 Cardiac implant (physical object) en Fully specified name Active Entire term case insensitive SNOMED CT core module


63 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Cardiac implant Is a Cardiovascular implant true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group
Coronary venous system mitral annuloplasty wire brace Is a True Cardiac implant Inferred relationship Existential restriction modifier
Cardiac myoplasty electrical stimulation system lead Is a True Cardiac implant Inferred relationship Existential restriction modifier
Cardiac occluder Is a True Cardiac implant Inferred relationship Existential restriction modifier
Heart ventricle reconfiguration implant Is a True Cardiac implant Inferred relationship Existential restriction modifier
Management of cardiac implant Direct device True Cardiac implant Inferred relationship Existential restriction modifier 1
Adjustment of cardiac implant Direct device True Cardiac implant Inferred relationship Existential restriction modifier 1
Cardiac assist implant Is a True Cardiac implant Inferred relationship Existential restriction modifier
Cardiac contractility modulation system pulse generator Is a True Cardiac implant Inferred relationship Existential restriction modifier
Atrial erosion caused by implanted device following atrial operation Causative agent True Cardiac implant Inferred relationship Existential restriction modifier 2
Erosion of right atrium due to and following implantation of device Causative agent True Cardiac implant Inferred relationship Existential restriction modifier 3
Erosion of left atrium due to and following implantation of device Causative agent True Cardiac implant Inferred relationship Existential restriction modifier 3
Cardiac insufficiency due to prosthesis Associated with True Cardiac implant Inferred relationship Existential restriction modifier 5
Percutaneous closure of prosthetic cardiac paravalvular leak using device Direct device True Cardiac implant Inferred relationship Existential restriction modifier 1
Temporary transvenous pacing Direct device False Cardiac implant Inferred relationship Existential restriction modifier 1
Transvenous pacemaker sensitivity measurement Direct device False Cardiac implant Inferred relationship Existential restriction modifier 1
Electrical capture by temporary transvenous pacing Direct device False Cardiac implant Inferred relationship Existential restriction modifier 1
Mechanical capture by temporary transvenous pacing Direct device False Cardiac implant Inferred relationship Existential restriction modifier 1
Infection of left ventricular assist device driveline (disorder) Associated with False Cardiac implant Inferred relationship Existential restriction modifier

Start Page 2 of 2


This concept is not in any reference sets

Back to Start