302324007: Adjustment of neurostimulator electrode in brain tissue (procedure)


Status: current, Sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
443933011 Adjustment of neurostimulator electrode in brain tissue en Synonym Active Entire term case insensitive SNOMED CT core module
698224010 Adjustment of neurostimulator electrode in brain tissue (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Adjustment of neurostimulator electrode in brain tissue Is a Neurostimulation procedure of brain tissue false Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Direct device Neurostimulator electrode false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Method Surgical action false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Method Adjustment of implant false Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Procedure site Occipital lobe structure false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Procedure site Parietal lobe structure false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Procedure site Frontal lobe structure false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Procedure site Temporal lobe structure false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Is a Adjustment of implant true Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Procedure site Brain structure false Inferred relationship Existential restriction modifier 2
Adjustment of neurostimulator electrode in brain tissue Revision status Revision - value false Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Is a Procedure categorized by device involved false Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Using Neurostimulator, device false Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Procedure device Implant, device false Inferred relationship Existential restriction modifier 2
Adjustment of neurostimulator electrode in brain tissue Direct device Implant, device false Inferred relationship Existential restriction modifier 3
Adjustment of neurostimulator electrode in brain tissue Method Repair - action false Inferred relationship Existential restriction modifier 3
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 2
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 2
Adjustment of neurostimulator electrode in brain tissue Is a Brain manipulation false Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Procedure site Brain tissue structure false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 2
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 2
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 2
Adjustment of neurostimulator electrode in brain tissue Is a Procedure on organ false Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Is a Procedure on brain true Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Procedure site - Indirect Brain tissue structure false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Direct device Implant, device false Inferred relationship Existential restriction modifier 2
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action false Inferred relationship Existential restriction modifier 2
Adjustment of neurostimulator electrode in brain tissue Is a Manipulation procedure by body site true Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Is a Operation on brain false Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Is a Adjustment false Inferred relationship Existential restriction modifier
Adjustment of neurostimulator electrode in brain tissue Direct device Neurostimulator electrode true Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Procedure site - Indirect Brain tissue structure true Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Method Adjustment - action true Inferred relationship Existential restriction modifier 1
Adjustment of neurostimulator electrode in brain tissue Is a Biomedical equipment procedure true Inferred relationship Existential restriction modifier

Inbound Relationships Type Active Source Characteristic Refinability Group