FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

241441008: Positron emission tomography myocardial rest study using N13 ammonia (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
361543019 PET myocardial rest study using N13 ammonia en Synonym Active Entire term case sensitive SNOMED CT core module
2609197016 Positron emission tomography myocardial rest study using N13 ammonia (procedure) en Fully specified name Active Only initial character case insensitive SNOMED CT core module
2619620017 Positron emission tomography myocardial rest study using N13 ammonia en Synonym Active Only initial character case insensitive SNOMED CT core module


3 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Positron emission tomography myocardial rest study using N13 ammonia Is a Positron emission tomography heart study true Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Method Radiographic imaging - action false Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Procedure site Thoracic structure false Inferred relationship Existential restriction modifier 2
Positron emission tomography myocardial rest study using N13 ammonia Method Investigation - action false Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Using Positron emission tomography unit, device false Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Method Radionuclide imaging - action false Inferred relationship Existential restriction modifier 1
Positron emission tomography myocardial rest study using N13 ammonia Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Procedure site Cardiac structure false Inferred relationship Existential restriction modifier 1
Positron emission tomography myocardial rest study using N13 ammonia Method Radionuclide imaging - action false Inferred relationship Existential restriction modifier 2
Positron emission tomography myocardial rest study using N13 ammonia Direct substance Radioactive isotope false Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Method Positron emission tomographic imaging - action true Inferred relationship Existential restriction modifier 1
Positron emission tomography myocardial rest study using N13 ammonia Method Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Positron emission tomography myocardial rest study using N13 ammonia Direct substance Ammonia (13-N) false Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Procedure site - Direct Heart structure false Inferred relationship Existential restriction modifier 1
Positron emission tomography myocardial rest study using N13 ammonia Is a Nuclear medicine study by site false Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Using substance Ammonia (13-N) false Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Procedure site - Direct Heart structure false Inferred relationship Existential restriction modifier 1
Positron emission tomography myocardial rest study using N13 ammonia Method Positron emission tomographic imaging - action false Inferred relationship Existential restriction modifier 1
Positron emission tomography myocardial rest study using N13 ammonia Using substance Radioactive isotope false Inferred relationship Existential restriction modifier 2
Positron emission tomography myocardial rest study using N13 ammonia Method Positron emission tomographic imaging - action false Inferred relationship Existential restriction modifier 2
Positron emission tomography myocardial rest study using N13 ammonia Method Positron emission tomographic imaging - action false Inferred relationship Existential restriction modifier 3
Positron emission tomography myocardial rest study using N13 ammonia Procedure site - Direct Heart structure false Inferred relationship Existential restriction modifier 3
Positron emission tomography myocardial rest study using N13 ammonia Using substance Ammonia (13-N) false Inferred relationship Existential restriction modifier 3
Positron emission tomography myocardial rest study using N13 ammonia Is a Radioisotope myocardial imaging procedure true Inferred relationship Existential restriction modifier
Positron emission tomography myocardial rest study using N13 ammonia Procedure site - Direct Myocardium structure true Inferred relationship Existential restriction modifier 1
Positron emission tomography myocardial rest study using N13 ammonia Using substance Ammonia (13-N) true Inferred relationship Existential restriction modifier 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Positron emission tomography electrocardiography gated myocardial rest study using N13 ammonia Is a True Positron emission tomography myocardial rest study using N13 ammonia Inferred relationship Existential restriction modifier
Positron emission tomography using nitrogen 13 ammonia with computed tomography myocardial rest study Is a True Positron emission tomography myocardial rest study using N13 ammonia Inferred relationship Existential restriction modifier
Positron emission tomography electrocardiography gated N13 ammonia myocardial rest study (procedure) Is a False Positron emission tomography myocardial rest study using N13 ammonia Inferred relationship Existential restriction modifier
Positron emission tomography with computed tomography myocardial rest study using nitrogen 13 ammonia Is a False Positron emission tomography myocardial rest study using N13 ammonia Inferred relationship Existential restriction modifier

This concept is not in any reference sets

Back to Start