FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

21032000: Cardiac mapping (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
35354013 Cardiac mapping en Synonym Active Entire term case insensitive SNOMED CT core module
750282015 Cardiac mapping (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


3 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Cardiac mapping Is a Electrocardiographic procedure false Inferred relationship Existential restriction modifier
Cardiac mapping Is a Cardiac electrophysiology true Inferred relationship Existential restriction modifier
Cardiac mapping Using Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier
Cardiac mapping Method Investigation - action false Inferred relationship Existential restriction modifier
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier
Cardiac mapping Method Measurement - action false Inferred relationship Existential restriction modifier 1
Cardiac mapping Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Cardiac mapping Direct device Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier
Cardiac mapping Using Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier 2
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Cardiac mapping Method Monitoring - action false Inferred relationship Existential restriction modifier 1
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Cardiac mapping Procedure site - Direct Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Cardiac mapping Using device Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier 1
Cardiac mapping Procedure site Structure of cardiovascular system true Inferred relationship Existential restriction modifier 1
Cardiac mapping Method Evaluation - action true Inferred relationship Existential restriction modifier 1
Cardiac mapping Method Evaluation - action false Inferred relationship Existential restriction modifier 1
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Cardiac mapping Method Measurement - action false Inferred relationship Existential restriction modifier 1
Cardiac mapping Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Cardiac mapping Has intent Diagnostic intent false Inferred relationship Existential restriction modifier 2

Inbound Relationships Type Active Source Characteristic Refinability Group
Percutaneous transluminal mapping of conducting system of heart Is a True Cardiac mapping Inferred relationship Existential restriction modifier
Intraoperative cardiac pacing and mapping Is a True Cardiac mapping Inferred relationship Existential restriction modifier

This concept is not in any reference sets

Back to Start