Status: retired, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2010. Module: SNOMED CT core module
Descriptions:
| Id | Description | Lang | Type | Status | Case? | Module | 
| 271363012 | Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | en | Synonym | Active | Entire term case insensitive | SNOMED CT core module | 
| 557767012 | Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis (procedure) | en | Fully specified name | Active | Entire term case insensitive | SNOMED CT core module | 
| Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values | 
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Is a | Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Cardiopulmonary circulatory system structure | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Surgical repair - action | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Entire subclavian artery | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Construction - action | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Repair - action | false | Inferred relationship | Existential restriction modifier | 1 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Using | Shunt | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Structure of intrathoracic systemic artery | false | Inferred relationship | Existential restriction modifier | 1 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Structure of pulmonary artery within lung | false | Inferred relationship | Existential restriction modifier | 1 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Intrathoracic arterial structure | false | Inferred relationship | Existential restriction modifier | 1 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Arterial graft | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Interposition anastomosis - action | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Arterial structure | false | Inferred relationship | Existential restriction modifier | 1 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Structure of subclavian artery | false | Inferred relationship | Existential restriction modifier | 1 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Bypass - action | false | Inferred relationship | Existential restriction modifier | 1 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Direct device | Shunt | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Intrathoracic cardiovascular structure | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Systemic circulatory system structure | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site | Structure of great blood vessel (organ) | false | Inferred relationship | Existential restriction modifier | ||
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Using device | Interposition shunt | false | Inferred relationship | Existential restriction modifier | 6 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site - Direct | Intrathoracic arterial structure | false | Inferred relationship | Existential restriction modifier | 5 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Using device | Interposition shunt | false | Inferred relationship | Existential restriction modifier | 7 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site - Direct | Pulmonary artery structure | false | Inferred relationship | Existential restriction modifier | 4 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site - Direct | Pulmonary artery structure | false | Inferred relationship | Existential restriction modifier | 7 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site - Indirect | Structure of pulmonary artery within lung | false | Inferred relationship | Existential restriction modifier | 2 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site - Direct | Structure of subclavian artery | false | Inferred relationship | Existential restriction modifier | 1 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site - Direct | Structure of subclavian artery | false | Inferred relationship | Existential restriction modifier | 3 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Procedure site - Direct | Structure of subclavian artery | false | Inferred relationship | Existential restriction modifier | 6 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Shunt - action | false | Inferred relationship | Existential restriction modifier | 1 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Shunt - action | false | Inferred relationship | Existential restriction modifier | 2 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Using device | Shunt | false | Inferred relationship | Existential restriction modifier | 1 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Side-to-side anastomosis | false | Inferred relationship | Existential restriction modifier | 3 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Side-to-side anastomosis | false | Inferred relationship | Existential restriction modifier | 4 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Using device | Shunt | false | Inferred relationship | Existential restriction modifier | 2 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Bypass - action | false | Inferred relationship | Existential restriction modifier | 2 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Bypass - action | false | Inferred relationship | Existential restriction modifier | 7 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Bypass - action | false | Inferred relationship | Existential restriction modifier | 6 | |
| Other specified creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis | Method | Anastomosis - action | false | Inferred relationship | Existential restriction modifier | 5 | 
| Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group | 
This concept is not in any reference sets