FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

175131000: Percutaneous transluminal electrophysiological studies on conducting system of heart (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status. Date: 31-Jan 2002. Module: SNOMED CT core module

Descriptions:

Id Description Lang Type Status Case? Module
271215012 Percutaneous transluminal electrophysiological studies on conducting system of heart en Synonym Active Entire term case insensitive SNOMED CT core module
557644019 Percutaneous transluminal electrophysiological studies on conducting system of heart (procedure) en Fully specified name Active Entire term case insensitive SNOMED CT core module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Percutaneous transluminal electrophysiological studies on conducting system of heart Is a Procedure for arrhythmia true Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Is a Electrocardiogram, intracardiac true Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Using Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Method Investigation - action false Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Cardiac conducting system structure false Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Access Percutaneous approach - access false Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Approach Transluminal approach false Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Has intent Diagnostic intent false Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Cardiac chamber structure false Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Method Measurement - action false Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Direct device Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Using Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Is a Procedure by transluminal approach false Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Method Monitoring - action false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Has focus Conduction disorder of the heart false Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Is a Examination of heart true Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Is a Functional assessment true Inferred relationship Existential restriction modifier
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site - Direct Cardiac chamber structure true Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site - Direct Cardiac conducting system structure false Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site - Direct Structure of cardiovascular system false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Method Functional assessment - action false Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Using device Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Method Monitoring - action false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site - Direct Cardiac chamber structure false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Using device Electrocardiographic monitor and recorder, device false Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Procedure site - Direct Cardiac conducting system structure true Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Access Percutaneous approach - access true Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Method Functional assessment - action true Inferred relationship Existential restriction modifier 1
Percutaneous transluminal electrophysiological studies on conducting system of heart Method Monitoring - action true Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Using device Electrocardiographic monitor and recorder, device true Inferred relationship Existential restriction modifier 2
Percutaneous transluminal electrophysiological studies on conducting system of heart Has focus Cardiac arrhythmia true Inferred relationship Existential restriction modifier 3

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start