FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

1464781000000105: Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive continuous glucose monitoring device (observable entity)

  • SNOMED CT Concept\Observable entity\Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive continuous glucose monitoring device

Status: current, Not sufficiently defined by necessary conditions definition status. Date: 23-Nov 2022. Module: SNOMED CT United Kingdom clinical extension module

Descriptions:

Id Description Lang Type Status Case? Module
2970831000000115 Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive continuous glucose monitoring device en Synonym Active Entire term case insensitive SNOMED CT United Kingdom clinical extension module
2970841000000112 Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive continuous glucose monitoring device (observable entity) en Fully specified name Active Entire term case insensitive SNOMED CT United Kingdom clinical extension module
2970851000000110 Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive CGM (continuous glucose monitoring) device en Synonym Active Only initial character case insensitive SNOMED CT United Kingdom clinical extension module


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive continuous glucose monitoring device Technique Measurement technique true Inferred relationship Existential restriction modifier 1
Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive continuous glucose monitoring device Is a Observable entity true Inferred relationship Existential restriction modifier
Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive continuous glucose monitoring device Direct site Dermis structure true Inferred relationship Existential restriction modifier 5
Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive continuous glucose monitoring device Property Time ratio true Inferred relationship Existential restriction modifier 2
Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive continuous glucose monitoring device Scale type Quantitative true Inferred relationship Existential restriction modifier 3
Percentage of time in target glucose range to total glucose monitoring time using minimally-invasive continuous glucose monitoring device Using device Blood glucose monitoring equipment true Inferred relationship Existential restriction modifier 4

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start