736702002: Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2018. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3521966011 Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
3521967019 Revision of biventricular permanent pacemaker lead using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3521968012 Fluoroscopy guided revision of biventricular permanent pacemaker lead en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Is a Revision of automatic implantable cardioverter/defibrillator true Inferred relationship Some
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Is a Operation on heart true Inferred relationship Some
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Is a Cardiac fluoroscopy false Inferred relationship Some
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Is a Cardiac pacemaker procedure false Inferred relationship Some
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Is a Fluoroscopic guidance false Inferred relationship Some
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 4
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) false Inferred relationship Some 4
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Heart structure false Inferred relationship Some 4
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Revision status Revision - value true Inferred relationship Some 5
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Method Surgical action true Inferred relationship Some 5
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Direct device Cardiac pacemaker lead true Inferred relationship Some 5
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Heart structure true Inferred relationship Some 5
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Revision status Revision - value true Inferred relationship Some 6
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Method Surgical action true Inferred relationship Some 6
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Direct device Implantable defibrillator true Inferred relationship Some 6
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Is a Fluoroscopy guided cardiac pacemaker procedure true Inferred relationship Some
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 2
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Heart structure true Inferred relationship Some 2
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Direct device Cardiac pacemaker lead true Inferred relationship Some 2
Revision of biventricular permanent pacemaker lead using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets