Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2011. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2898720011 | Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2901486013 | Insertion of permanent cardiac pacemaker pulse generator and electrode | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2901487016 | Insertion of permanent pacemaker system | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | Is a | Insertion of intracardiac pacemaker | true | Inferred relationship | Some | ||
Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | Is a | Insertion of pacemaker pulse generator | true | Inferred relationship | Some | ||
Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | Method | Insertion - action (qualifier value) | true | Inferred relationship | Some | 1 | |
Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | Direct device | Pacemaker pulse generator | true | Inferred relationship | Some | 2 | |
Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | Direct device | Cardiac pacemaker electrode | false | Inferred relationship | Some | 1 | |
Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | Procedure site - Indirect (attribute) | Heart structure | true | Inferred relationship | Some | 1 | |
Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | Method | Insertion - action (qualifier value) | true | Inferred relationship | Some | 2 | |
Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | Direct device | Intracardiac pacemaker | true | Inferred relationship | Some | 1 | |
Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | Method | Insertion - action (qualifier value) | false | Inferred relationship | Some | 3 | |
Insertion of permanent cardiac pacemaker pulse generator and electrode (procedure) | Direct device | Biomedical device | false | Inferred relationship | Some | 3 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets