FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

442885001: Excision of flexor tendon of finger and implantation of synthetic rod (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2010. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2833935016 Excision of flexor tendon of finger and implantation of synthetic rod (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2837635019 Excision of flexor tendon of finger and implantation of synthetic rod en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Is a Hand implantation false Inferred relationship Some
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Is a Insertion of therapeutic device false Inferred relationship Some
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Is a Excision of flexor tendon of finger true Inferred relationship Some
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Method Excision - action (qualifier value) false Inferred relationship Some 1
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Procedure site - Direct (attribute) Structure of flexor tendon within finger false Inferred relationship Some 1
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Method Surgical insertion - action (qualifier value) false Inferred relationship Some 2
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Direct device Implant false Inferred relationship Some 2
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Procedure site - Indirect (attribute) Finger structure false Inferred relationship Some 2
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Method Excision - action (qualifier value) true Inferred relationship Some 1
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Procedure site - Direct (attribute) Structure of flexor tendon within finger true Inferred relationship Some 1
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Procedure site - Indirect (attribute) Finger structure true Inferred relationship Some 2
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Direct device Implant true Inferred relationship Some 2
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Method Surgical insertion - action (qualifier value) true Inferred relationship Some 2
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Is a Procedure categorized by device involved false Inferred relationship Some
Excision of flexor tendon of finger and implantation of synthetic rod (procedure) Is a Insertion procedure (procedure) true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start