FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.13  |  FHIR Version n/a  User: [n/a]

169294009: Half-deep therapy 60-150 kV (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
262756010 Half-deep therapy 60-150 kV en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core
551115014 Half-deep therapy 60-150 kV (procedure) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Half-deep therapy 60-150 kV Is a Superficial teletherapy procedure, Grenz type false Inferred relationship Some
Half-deep therapy 60-150 kV Has intent Therapeutic false Inferred relationship Some 1
Half-deep therapy 60-150 kV Method Action false Inferred relationship Some
Half-deep therapy 60-150 kV Using Grenz radiation false Inferred relationship Some
Half-deep therapy 60-150 kV Using Radioactivity false Inferred relationship Some
Half-deep therapy 60-150 kV Using Non-ionizing radiation false Inferred relationship Some
Half-deep therapy 60-150 kV Using energy (attribute) Grenz radiation false Inferred relationship Some
Half-deep therapy 60-150 kV Using energy (attribute) Ionizing electromagnetic radiation false Inferred relationship Some 2
Half-deep therapy 60-150 kV Is a Superficial radiation therapy true Inferred relationship Some
Half-deep therapy 60-150 kV Using energy (attribute) Radiation false Inferred relationship Some 1
Half-deep therapy 60-150 kV Using energy (attribute) Ionizing radiation false Inferred relationship Some 1
Half-deep therapy 60-150 kV Method Administration - action false Inferred relationship Some 3
Half-deep therapy 60-150 kV Using device (attribute) External beam radiation therapy radionuclide system (physical object) false Inferred relationship Some 3
Half-deep therapy 60-150 kV Using energy (attribute) Ionizing radiation false Inferred relationship Some 3
Half-deep therapy 60-150 kV Method Administration - action true Inferred relationship Some 1
Half-deep therapy 60-150 kV Procedure site - Direct (attribute) Skin structure true Inferred relationship Some 1
Half-deep therapy 60-150 kV Using device (attribute) External beam radiation therapy radionuclide system (physical object) true Inferred relationship Some 1
Half-deep therapy 60-150 kV Is a X-ray beam therapy true Inferred relationship Some
Half-deep therapy 60-150 kV Using energy (attribute) X-ray true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group