1156708005: Low dose rate brachytherapy using temporary radioactive source (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2021. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
4575706018 LDR (low dose rate) brachytherapy temporary placement en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
4575709013 Low dose rate brachytherapy using temporary radioactive source en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
4575710015 Low dose rate brachytherapy using temporary radioactive source (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
4575717017 Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. en Definition Active Entire term case sensitive (core metadata concept) SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Low dose rate brachytherapy using temporary radioactive source Has intent Therapeutic false Inferred relationship Some 2
Low dose rate brachytherapy using temporary radioactive source Using energy (attribute) Radiation false Inferred relationship Some 2
Low dose rate brachytherapy using temporary radioactive source Using substance (attribute) Radioactive isotope false Inferred relationship Some 1
Low dose rate brachytherapy using temporary radioactive source Is a Low dose rate brachytherapy true Inferred relationship Some
Low dose rate brachytherapy using temporary radioactive source Method Brachytherapy - action false Inferred relationship Some 1
Low dose rate brachytherapy using temporary radioactive source Using device (attribute) Radioactive implant false Inferred relationship Some 1
Low dose rate brachytherapy using temporary radioactive source Using device (attribute) Brachytherapy implant false Inferred relationship Some 1
Low dose rate brachytherapy using temporary radioactive source Using energy (attribute) Radiation false Inferred relationship Some 1
Low dose rate brachytherapy using temporary radioactive source Is a Temporary implant radiotherapy true Inferred relationship Some
Low dose rate brachytherapy using temporary radioactive source Method Implantation - action true Inferred relationship Some 1
Low dose rate brachytherapy using temporary radioactive source Direct device Temporary brachytherapy implant (physical object) true Inferred relationship Some 1
Low dose rate brachytherapy using temporary radioactive source Method Administration - action true Inferred relationship Some 2
Low dose rate brachytherapy using temporary radioactive source Using energy (attribute) Ionizing radiation true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group