Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2021. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
4575706018 | LDR (low dose rate) brachytherapy temporary placement | en | Synonym (core metadata concept) | Active | Entire term case sensitive (core metadata concept) | SNOMED CT core |
4575709013 | Low dose rate brachytherapy using temporary radioactive source | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
4575710015 | Low dose rate brachytherapy using temporary radioactive source (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
4575717017 | Radiation treatment that irradiates a treatment volume with temporarily placed radiation sources delivering low dose rates (typically less than or equal to 2 Gy/hour). All sources of radiation are removed at the completion of treatment. | en | Definition | Active | Entire term case sensitive (core metadata concept) | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Low dose rate brachytherapy using temporary radioactive source | Has intent | Therapeutic | false | Inferred relationship | Some | 2 | |
Low dose rate brachytherapy using temporary radioactive source | Using energy (attribute) | Radiation | false | Inferred relationship | Some | 2 | |
Low dose rate brachytherapy using temporary radioactive source | Using substance (attribute) | Radioactive isotope | false | Inferred relationship | Some | 1 | |
Low dose rate brachytherapy using temporary radioactive source | Is a | Low dose rate brachytherapy | true | Inferred relationship | Some | ||
Low dose rate brachytherapy using temporary radioactive source | Method | Brachytherapy - action | false | Inferred relationship | Some | 1 | |
Low dose rate brachytherapy using temporary radioactive source | Using device (attribute) | Radioactive implant | false | Inferred relationship | Some | 1 | |
Low dose rate brachytherapy using temporary radioactive source | Using device (attribute) | Brachytherapy implant | false | Inferred relationship | Some | 1 | |
Low dose rate brachytherapy using temporary radioactive source | Using energy (attribute) | Radiation | false | Inferred relationship | Some | 1 | |
Low dose rate brachytherapy using temporary radioactive source | Is a | Temporary implant radiotherapy | true | Inferred relationship | Some | ||
Low dose rate brachytherapy using temporary radioactive source | Method | Implantation - action | true | Inferred relationship | Some | 1 | |
Low dose rate brachytherapy using temporary radioactive source | Direct device | Temporary brachytherapy implant (physical object) | true | Inferred relationship | Some | 1 | |
Low dose rate brachytherapy using temporary radioactive source | Method | Administration - action | true | Inferred relationship | Some | 2 | |
Low dose rate brachytherapy using temporary radioactive source | Using energy (attribute) | Ionizing radiation | true | Inferred relationship | Some | 2 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Reference Sets