FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

169296006: Ultrahard X-rays 400-2000 kV (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
262761012 Ultrahard X-rays 400-2000 kV en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
551117018 Ultrahard X-rays 400-2000 kV (procedure) en Fully specified name Active Entire term case sensitive (core metadata concept) SNOMED CT core
3108711000005113 usædvanlig stærk røntgen, 400-2000 kV da Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) Danish module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Ultrahard X-rays 400-2000 kV (procedure) Is a Megavoltage radiation therapy false Inferred relationship Some
Ultrahard X-rays 400-2000 kV (procedure) Has intent Therapeutic false Inferred relationship Some 1
Ultrahard X-rays 400-2000 kV (procedure) Method Action false Inferred relationship Some
Ultrahard X-rays 400-2000 kV (procedure) Using Radioactivity false Inferred relationship Some
Ultrahard X-rays 400-2000 kV (procedure) Using Electromagnetic radiation of wavelength between approximately 001 nm and 10 nm false Inferred relationship Some
Ultrahard X-rays 400-2000 kV (procedure) Using Non-ionizing radiation false Inferred relationship Some
Ultrahard X-rays 400-2000 kV (procedure) Using energy (attribute) Electromagnetic radiation of wavelength between approximately 001 nm and 10 nm false Inferred relationship Some 2
Ultrahard X-rays 400-2000 kV (procedure) Using energy (attribute) Radiation false Inferred relationship Some 1
Ultrahard X-rays 400-2000 kV (procedure) Using energy (attribute) Ionizing radiation false Inferred relationship Some 1
Ultrahard X-rays 400-2000 kV (procedure) Method Administration - action (qualifier value) false Inferred relationship Some 3
Ultrahard X-rays 400-2000 kV (procedure) Using device (attribute) External beam radiation therapy radionuclide system (physical object) false Inferred relationship Some 3
Ultrahard X-rays 400-2000 kV (procedure) Using energy (attribute) Ionizing radiation false Inferred relationship Some 3
Ultrahard X-rays 400-2000 kV (procedure) Is a External beam radiation therapy by linear accelerator (procedure) true Inferred relationship Some
Ultrahard X-rays 400-2000 kV (procedure) Method Administration - action (qualifier value) true Inferred relationship Some 1
Ultrahard X-rays 400-2000 kV (procedure) Using device (attribute) Linear accelerator system (physical object) true Inferred relationship Some 1
Ultrahard X-rays 400-2000 kV (procedure) Using energy (attribute) Electromagnetic radiation of wavelength between approximately 001 nm and 10 nm true Inferred relationship Some 1
Ultrahard X-rays 400-2000 kV (procedure) Is a X-ray beam therapy true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start