FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

711504009: Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2015. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
3078690014 Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
3078697012 Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent (procedure) en Fully specified name Active Entire term case sensitive (core metadata concept) SNOMED CT core
3078843014 Doppler ultrasound of transjugular intrahepatic portosystemic shunt stent en Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT core
3808091000052117 dopplerultraljudsundersökning av stent i transjugulär intrahepatisk portosystemisk shunt sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Is a Ultrasonography of transjugular intrahepatic portosystemic shunt stent (procedure) true Inferred relationship Some
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Is a Doppler ultrasonography of portal vein false Inferred relationship Some
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Has intent Diagnostic intent (qualifier value) false Inferred relationship Some 2
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Method Ultrasound imaging - action (qualifier value) false Inferred relationship Some 4
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Indirect morphology Transjugular intrahepatic portosystemic shunt (morphologic abnormality) false Inferred relationship Some 4
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Direct device Stent false Inferred relationship Some 4
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Procedure site - Direct (attribute) Portal vein structure false Inferred relationship Some 4
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Using device (attribute) Doppler device false Inferred relationship Some 4
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Method Doppler ultrasound imaging - action (qualifier value) true Inferred relationship Some 1
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Indirect morphology Transjugular intrahepatic portosystemic shunt (morphologic abnormality) true Inferred relationship Some 1
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Direct device Stent true Inferred relationship Some 1
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Is a Procedure on abdomen true Inferred relationship Some
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Is a Doppler ultrasonography true Inferred relationship Some
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Is a Cardiovascular investigation true Inferred relationship Some
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Is a Procedure on vein (procedure) true Inferred relationship Some
Doppler ultrasonography of transjugular intrahepatic portosystemic shunt stent Procedure site - Indirect (attribute) Portal vein structure true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start