FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

450821005: Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2012. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2917013017 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2917046011 Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3616231000052116 byte av pulsgenerator i implanterbar defibrillator under röntgengenomlysning sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Fluoroscopic guidance true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) false Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Automatic defibrillator procedure true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Replacement of device (procedure) true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Removal of cardiac pacemaker true Inferred relationship Some
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Replacement - action false Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Pacemaker pulse generator false Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Indirect device Implantable defibrillator false Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Replacement - action true Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Pacemaker pulse generator true Inferred relationship Some 2
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 3
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Indirect device Implantable defibrillator true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start