Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2012. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2917013017 | Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2917046011 | Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
3616231000052116 | byte av pulsgenerator i implanterbar defibrillator under röntgengenomlysning | sv | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Sweden NRC maintained module (core metadata concept) |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Is a | Fluoroscopic guidance | true | Inferred relationship | Some | ||
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | false | Inferred relationship | Some | 3 | |
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Has intent | Guidance intent (qualifier value) | false | Inferred relationship | Some | 3 | |
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Is a | Automatic defibrillator procedure | true | Inferred relationship | Some | ||
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Is a | Replacement of device (procedure) | true | Inferred relationship | Some | ||
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Is a | Removal of cardiac pacemaker | true | Inferred relationship | Some | ||
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Method | Replacement - action | false | Inferred relationship | Some | 2 | |
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Direct device | Pacemaker pulse generator | false | Inferred relationship | Some | 2 | |
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Indirect device | Implantable defibrillator | false | Inferred relationship | Some | 2 | |
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Method | Replacement - action | true | Inferred relationship | Some | 2 | |
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Method | Fluoroscopic imaging - action (qualifier value) | true | Inferred relationship | Some | 3 | |
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Direct device | Pacemaker pulse generator | true | Inferred relationship | Some | 2 | |
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Has intent | Guidance intent (qualifier value) | true | Inferred relationship | Some | 3 | |
Replacement of pulse generator of implantable cardioverter defibrillator using fluoroscopic guidance (procedure) | Indirect device | Implantable defibrillator | true | Inferred relationship | Some | 2 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets