FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

443171000: Single photon emission computed tomography with computed tomography of entire skeleton (procedure)


    Status: retired, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2019. Module: SNOMED CT core

    Descriptions:

    Id Description Lang Type Status Case? Module
    2835133014 Single photon emission computed tomography with computed tomography of entire skeleton (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
    2837860016 Single photon emission computed tomography with computed tomography of entire skeleton en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
    3134601000052111 enfotonstomografi med datortomografi av hela skelettet sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)
    4112261000052112 SPECT med datortomografi av hela skelettet sv Synonym (core metadata concept) Active Entire term case sensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


    0 descendants.

    Expanded Value Set


    Outbound Relationships Type Target Active Characteristic Refinability Group Values
    SPECT med datortomografi av hela skelettet Is a SPECT av hela skelettet false Inferred relationship Some
    SPECT med datortomografi av hela skelettet Is a CT of musculoskeletal system structures false Inferred relationship Some
    SPECT med datortomografi av hela skelettet Method Single photon emission computed tomography - action (qualifier value) false Inferred relationship Some 2
    SPECT med datortomografi av hela skelettet Procedure site - Direct (attribute) Entire skeleton false Inferred relationship Some 2
    SPECT med datortomografi av hela skelettet Method Computed tomography imaging - action (qualifier value) false Inferred relationship Some 1
    SPECT med datortomografi av hela skelettet Procedure site - Direct (attribute) Entire skeleton false Inferred relationship Some 1
    SPECT med datortomografi av hela skelettet Using substance (attribute) Radioactive isotope false Inferred relationship Some 2
    SPECT med datortomografi av hela skelettet Is a Single photon emission computed tomography with computed tomography (procedure) false Inferred relationship Some

    Inbound Relationships Type Active Source Characteristic Refinability Group

    Reference Sets

    Concept inactivation indicator reference set

    POSSIBLY EQUIVALENT TO association reference set (foundation metadata concept)

    Back to Start