FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

442903009: Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2010. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2834298017 Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2837510016 Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
3226251000052115 öppen reposition av intertrokantär femurfraktur med intern fixering med intramedullärt implantat, skruv och cerklagetråd sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)
4990021000052111 öppen reponering av intertrokantär femurfraktur med intern fixering med intramedullärt implantat, skruv och cerklagetråd sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Is a Fixation of fracture using screws true Inferred relationship Some
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Is a Open reduction of fracture of femur with internal fixation true Inferred relationship Some
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Is a Fixation of fracture using wire true Inferred relationship Some
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Is a Fixation of hip false Inferred relationship Some
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Method Open reduction - action (qualifier value) true Inferred relationship Some 1
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Using device (attribute) Bone wire true Inferred relationship Some 2
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Direct morphology Fracture true Inferred relationship Some 3
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Method Fixation - action true Inferred relationship Some 2
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Method Fixation - action true Inferred relationship Some 3
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Direct morphology Fracture true Inferred relationship Some 1
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Direct morphology Fracture true Inferred relationship Some 2
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Procedure site - Direct (attribute) Intertrochanteric structure of femur true Inferred relationship Some 1
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Procedure site - Direct (attribute) Intertrochanteric structure of femur true Inferred relationship Some 2
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Procedure site - Direct (attribute) Intertrochanteric structure of femur true Inferred relationship Some 3
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Using device (attribute) Bone screw true Inferred relationship Some 3
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) Is a Operative procedure on hip (procedure) true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start