Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2010. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
2834298017 | Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
2837510016 | Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core |
3226251000052115 | öppen reposition av intertrokantär femurfraktur med intern fixering med intramedullärt implantat, skruv och cerklagetråd | sv | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Sweden NRC maintained module (core metadata concept) |
4990021000052111 | öppen reponering av intertrokantär femurfraktur med intern fixering med intramedullärt implantat, skruv och cerklagetråd | sv | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Sweden NRC maintained module (core metadata concept) |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Is a | Fixation of fracture using screws | true | Inferred relationship | Some | ||
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Is a | Open reduction of fracture of femur with internal fixation | true | Inferred relationship | Some | ||
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Is a | Fixation of fracture using wire | true | Inferred relationship | Some | ||
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Is a | Fixation of hip | false | Inferred relationship | Some | ||
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Method | Open reduction - action (qualifier value) | true | Inferred relationship | Some | 1 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Using device (attribute) | Bone wire | true | Inferred relationship | Some | 2 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Direct morphology | Fracture | true | Inferred relationship | Some | 3 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Method | Fixation - action | true | Inferred relationship | Some | 2 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Method | Fixation - action | true | Inferred relationship | Some | 3 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Direct morphology | Fracture | true | Inferred relationship | Some | 1 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Direct morphology | Fracture | true | Inferred relationship | Some | 2 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Procedure site - Direct (attribute) | Intertrochanteric structure of femur | true | Inferred relationship | Some | 1 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Procedure site - Direct (attribute) | Intertrochanteric structure of femur | true | Inferred relationship | Some | 2 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Procedure site - Direct (attribute) | Intertrochanteric structure of femur | true | Inferred relationship | Some | 3 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Using device (attribute) | Bone screw | true | Inferred relationship | Some | 3 | |
Open reduction of intertrochanteric fracture of femur with internal fixation using intramedullary implant, screw, and cerclage wiring (procedure) | Is a | Operative procedure on hip (procedure) | true | Inferred relationship | Some |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets