FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.21  |  FHIR Version n/a  User: [n/a]

395721008: Removal of electronic stimulator of brain with synchronous replacement (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2003. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
1469661011 Removal of electronic stimulator of brain with synchronous replacement (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
1489364019 Removal of electronic stimulator of brain with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1494701010 Removal of neurostimulator of brain with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1494702015 Removal of intracranial neuropacemaker with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1494703013 Removal of intracranial neurostimulator with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1494704019 Removal of intracranial pacemaker with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1494705018 Removal of intracranial electronic stimulator with synchronous replacement en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
1759151000052116 avlägsnande av elektronisk stimulator från hjärnan med samtidigt byte sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Removal of electronic stimulator of brain with synchronous replacement (procedure) Is a Removal of device from central nervous system true Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) Is a Cardiac pacemaker procedure false Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) Is a avlägsnande av behandlingsutrustning false Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) Is a Operation on brain false Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) Method Surgical action false Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) Method Removal - action false Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) Direct device neuropacemakeranordning false Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) Procedure site Brain structure false Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) Procedure site Brain structure false Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) Procedure site Brain structure false Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) Procedure site Brain structure false Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) Is a Replacement of device (procedure) true Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) Method Replacement - action false Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) Procedure site - Indirect (attribute) Brain structure false Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) Is a Removal of object from brain tissue (procedure) false Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) Is a Operation on brain true Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) Method Surgical action true Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) Direct device neuropacemakeranordning false Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) Method Replacement - action true Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) Procedure site - Indirect (attribute) Brain structure true Inferred relationship Some 1
Removal of electronic stimulator of brain with synchronous replacement (procedure) Procedure site Brain structure true Inferred relationship Some 2
Removal of electronic stimulator of brain with synchronous replacement (procedure) Is a Removal of device from head true Inferred relationship Some
Removal of electronic stimulator of brain with synchronous replacement (procedure) Direct device Neurostimulator true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start