FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.7.10  |  FHIR Version n/a  User: [n/a]

272300006: Closed reduction of fracture of femur with internal fixation (procedure)


Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2007. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
407419015 Closed reduction of fracture of femur with internal fixation en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core
664806018 Closed reduction of fracture of femur with internal fixation (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core
2193761000052116 sluten reposition av fraktur på femur med intern fixering sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)
4991991000052116 sluten reponering av fraktur på femur med intern fixering sv Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT Sweden NRC maintained module (core metadata concept)


16 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Closed reduction of fracture of femur with internal fixation Is a Primary closed reduction and internal fixation of fracture false Inferred relationship Some
Closed reduction of fracture of femur with internal fixation Method Reduction - action false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Procedure site Bone structure false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Revision status Principal false Inferred relationship Some
Closed reduction of fracture of femur with internal fixation Access Open approach false Inferred relationship Some
Closed reduction of fracture of femur with internal fixation Procedure site Skeletal system structure false Inferred relationship Some
Closed reduction of fracture of femur with internal fixation Access Closed approach false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Procedure site Bone structure false Inferred relationship Some 4
Closed reduction of fracture of femur with internal fixation Method Fixation - action true Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Revision status Primary operation false Inferred relationship Some
Closed reduction of fracture of femur with internal fixation Direct device Orthopedic internal fixation system false Inferred relationship Some
Closed reduction of fracture of femur with internal fixation Procedure site Bone structure false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Procedure site Bone structure false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Using Orthopedic internal fixation system false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Procedure site Bone structure false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Procedure site Bone structure false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Direct device Orthopedic internal fixation system false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Procedure site - Indirect (attribute) Bone structure false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Is a Closed reduction of fracture of femur true Inferred relationship Some
Closed reduction of fracture of femur with internal fixation Procedure site - Direct (attribute) Bone structure false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Using device (attribute) Orthopedic internal fixation system false Inferred relationship Some 3
Closed reduction of fracture of femur with internal fixation Using device (attribute) Orthopedic internal fixation system false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Using device (attribute) Orthopedic internal fixation system false Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Procedure site - Direct (attribute) Bone structure of femur false Inferred relationship Some 3
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture false Inferred relationship Some 3
Closed reduction of fracture of femur with internal fixation Method Reduction - action false Inferred relationship Some 3
Closed reduction of fracture of femur with internal fixation Method Reduction - action false Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Is a Internal fixation of femur true Inferred relationship Some
Closed reduction of fracture of femur with internal fixation Is a Closed reduction of fracture with internal fixation true Inferred relationship Some
Closed reduction of fracture of femur with internal fixation Method Closed reduction - action (qualifier value) true Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture true Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Direct morphology Fracture true Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Procedure site - Direct (attribute) Bone structure of femur true Inferred relationship Some 1
Closed reduction of fracture of femur with internal fixation Procedure site - Direct (attribute) Bone structure of femur true Inferred relationship Some 2
Closed reduction of fracture of femur with internal fixation Using device (attribute) Orthopedic internal fixation system true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group
Primary closed reduction and internal fixation of proximal femoral fracture with screw/nail and plate device Is a True Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Closed reduction and internal fixation of proximal femoral fracture with Richard's cannulated hip screw Is a True Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw Is a True Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Closed reduction of intracapsular fracture of neck of femur and fixation using Smith-Petersen nail Is a True Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Primary closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device (procedure) Is a True Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Primary closed reduction and internal fixation of proximal femoral fracture with screw/nail device alone Is a False Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and intramedullary device Is a True Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail device alone Is a False Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Revision to closed reduction and internal fixation of proximal femoral fracture with screw/nail and plate device Is a False Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Closed reduction and internal fixation of proximal femoral fracture with screw/nail device alone Is a False Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Closed reduction of fracture of proximal femur and internal fixation using bone screw (procedure) Is a True Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Closed reduction of fracture of proximal femur and internal fixation using bone wire (procedure) Is a True Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Closed reduction of fracture of femur and internal fixation using bone plate Is a True Closed reduction of fracture of femur with internal fixation Inferred relationship Some
Closed reduction of fracture of femur and internal fixation using bone nail Is a True Closed reduction of fracture of femur with internal fixation Inferred relationship Some

Reference Sets

Description inactivation indicator reference set

GB English

US English

Back to Start