Status: current, Primitive. Date: 31-Jan 2017. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
3331166013 | Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome (disorder) | en | Fully specified name | Active | Case insensitive | SNOMED CT core |
3331167016 | Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | en | Synonym | Active | Case insensitive | SNOMED CT core |
3331168014 | A very rare heart-hand syndrome that has characteristics of a variety of cardiovascular anomalies including patent arterial duct, bicuspid aortic valve and pseudocoarctation of the aorta in conjunction with hand anomalies such as brachydactyly and ulnar ray derivative i.e. fifth metacarpal hypoplasia. Transmission is most likely autosomal dominant although X-linked dominance could not be excluded. | en | Definition | Active | Case sensitive | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Pathological process | Pathological developmental process | true | Inferred relationship | Some | 1 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Pathological process | Pathological developmental process | true | Inferred relationship | Some | 2 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Occurrence | Congenital | true | Inferred relationship | Some | 1 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Associated morphology | Congenital dysplasia | false | Inferred relationship | Some | 1 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Finding site | Bone structure of hand | true | Inferred relationship | Some | 1 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Associated morphology | Morphologically abnormal structure | true | Inferred relationship | Some | 2 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Associated morphology | Dysplasia | true | Inferred relationship | Some | 1 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Is a | Developmental hereditary disorder | true | Inferred relationship | Some | ||
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Is a | Congenital anomaly of hand | true | Inferred relationship | Some | ||
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Is a | Dysostosis | true | Inferred relationship | Some | ||
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Is a | Finding of bone in hand | true | Inferred relationship | Some | ||
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Is a | Cardiovascular system hereditary disorder | true | Inferred relationship | Some | ||
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Is a | Congenital anomaly of cardiovascular structure of trunk | true | Inferred relationship | Some | ||
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Is a | Inherited disorder of connective tissue | false | Inferred relationship | Some | ||
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Is a | Hereditary disorder of musculoskeletal system | true | Inferred relationship | Some | ||
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Occurrence | Congenital | true | Inferred relationship | Some | 2 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Finding site | Cardiovascular structure of trunk | true | Inferred relationship | Some | 2 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Occurrence | Congenital | false | Inferred relationship | Some | 3 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Associated morphology | Congenital dysplasia | false | Inferred relationship | Some | 2 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Finding site | Bone structure of hand | false | Inferred relationship | Some | 2 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Associated morphology | Developmental abnormality | false | Inferred relationship | Some | 3 | |
Patent ductus arteriosus, bicuspid aortic valve, hand anomaly syndrome | Finding site | Cardiovascular structure of trunk | false | Inferred relationship | Some | 3 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Reference Sets
Australian emergency department reference set
Clinical finding foundation reference set
Musculoskeletal finding reference set
Cardiovascular finding reference set
Problem/Diagnosis reference set