64690006: Mechanical complication due to ocular lens prosthesis (disorder)


    Status: retired, Primitive. Date: 31-Jan 2013. Module: SNOMED CT core

    Descriptions:

    Id Description Lang Type Status Case? Module
    107508019 Mechanical complication due to ocular lens prosthesis en Synonym Active Case insensitive SNOMED CT core
    2474908015 Mechanical complication due to intraocular lens implant en Synonym Active Case insensitive SNOMED CT core
    804110012 Mechanical complication due to ocular lens prosthesis (disorder) en Fully specified name Active Case insensitive SNOMED CT core


    0 descendants.

    Expanded Value Set


    Outbound Relationships Type Target Active Characteristic Refinability Group Values
    Mechanical complication due to intraocular lens implant Temporally follows Surgical procedure false Inferred relationship Some
    Mechanical complication due to intraocular lens implant Temporally follows Surgical procedure false Inferred relationship Some
    Mechanical complication due to intraocular lens implant Temporally follows Implantation false Inferred relationship Some
    Mechanical complication due to intraocular lens implant Is a Complication of implant false Inferred relationship Some
    Mechanical complication due to intraocular lens implant Causative agent Intraocular lens implant false Inferred relationship Some
    Mechanical complication due to intraocular lens implant Following Implantation false Inferred relationship Some
    Mechanical complication due to intraocular lens implant Associated with Procedure false Inferred relationship Some
    Mechanical complication due to intraocular lens implant Causative agent Implantable lens false Inferred relationship Some

    Inbound Relationships Type Active Source Characteristic Refinability Group
    Dislocated intraocular lens Is a False Mechanical complication due to intraocular lens implant Inferred relationship Some
    Deposits on intraocular lens Is a False Mechanical complication due to intraocular lens implant Inferred relationship Some
    YAG laser pit in intraocular lens Is a False Mechanical complication due to intraocular lens implant Inferred relationship Some
    Silicone oil droplets on intraocular lens Is a False Mechanical complication due to intraocular lens implant Inferred relationship Some
    Decentered intraocular lens implant Is a False Mechanical complication due to intraocular lens implant Inferred relationship Some