FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

60633004: Subcutaneous mammectomy of bilateral breasts with synchronous implants (procedure)


Status: current, Primitive. Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
100736013 Bilateral mastectomy with preservation of skin and nipple with synchronous implant en Synonym Active Case insensitive SNOMED CT core
1908911000168115 Bilateral subcutaneous mastectomy with synchronous implant en Synonym Active Case insensitive SNOMED Clinical Terms Australian extension
3432231000168119 Bilateral nipple-sparing mastectomy with synchronous implant en Synonym Active Case insensitive SNOMED Clinical Terms Australian extension
3432241000168111 Bilateral NSP (nipple-sparing mastectomy) with synchronous implant en Synonym Active Initial character case insensitive SNOMED Clinical Terms Australian extension
4651095010 Subcutaneous mammectomy of bilateral breasts with synchronous implants (procedure) en Fully specified name Active Case insensitive SNOMED CT core
4651096011 Subcutaneous mammectomy of bilateral breasts with synchronous implants en Synonym Active Case insensitive SNOMED CT core
4651097019 Subcutaneous mammectomy of both breasts with synchronous implants en Synonym Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site - Direct Structure of breast false Inferred relationship Some 5
Bilateral nipple-sparing mastectomy with synchronous implant Method Repair - action false Inferred relationship Some 5
Bilateral nipple-sparing mastectomy with synchronous implant Is a Nipple-sparing mastectomy of right breast with prosthetic implant true Inferred relationship Some
Bilateral nipple-sparing mastectomy with synchronous implant Is a Nipple-sparing mastectomy of left breast with prosthetic implant true Inferred relationship Some
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site - Indirect Right breast structure true Inferred relationship Some 3
Bilateral nipple-sparing mastectomy with synchronous implant Method Surgical insertion - action true Inferred relationship Some 3
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site - Indirect Left breast structure true Inferred relationship Some 4
Bilateral nipple-sparing mastectomy with synchronous implant Method Surgical insertion - action true Inferred relationship Some 4
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site Body structure false Inferred relationship Some 2
Bilateral nipple-sparing mastectomy with synchronous implant Method Insertion - action false Inferred relationship Some 1
Bilateral nipple-sparing mastectomy with synchronous implant Is a Bilateral mastectomy false Inferred relationship Some
Bilateral nipple-sparing mastectomy with synchronous implant Is a Nipple-sparing mastectomy with synchronous implant false Inferred relationship Some
Bilateral nipple-sparing mastectomy with synchronous implant Direct device Implant false Inferred relationship Some
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site - Direct Both breasts false Inferred relationship Some 2
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site - Indirect Both breasts false Inferred relationship Some 1
Bilateral nipple-sparing mastectomy with synchronous implant Is a Insertion of bilateral breast prostheses true Inferred relationship Some
Bilateral nipple-sparing mastectomy with synchronous implant Method Excision - action true Inferred relationship Some 1
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site - Direct Right breast structure true Inferred relationship Some 2
Bilateral nipple-sparing mastectomy with synchronous implant Method Insertion - action false Inferred relationship Some 4
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site - Indirect Right breast structure false Inferred relationship Some 4
Bilateral nipple-sparing mastectomy with synchronous implant Method Excision - action true Inferred relationship Some 2
Bilateral nipple-sparing mastectomy with synchronous implant Method Insertion - action false Inferred relationship Some 3
Bilateral nipple-sparing mastectomy with synchronous implant Direct device Breast prosthesis true Inferred relationship Some 3
Bilateral nipple-sparing mastectomy with synchronous implant Direct device Breast prosthesis true Inferred relationship Some 4
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site - Direct Left breast structure true Inferred relationship Some 1
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site - Indirect Left breast structure false Inferred relationship Some 3
Bilateral nipple-sparing mastectomy with synchronous implant Is a Bilateral nipple-sparing mastectomy true Inferred relationship Some
Bilateral nipple-sparing mastectomy with synchronous implant Method Excision - action false Inferred relationship Some 2
Bilateral nipple-sparing mastectomy with synchronous implant Extent Total false Inferred relationship Some
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site Entire breast false Inferred relationship Some 1
Bilateral nipple-sparing mastectomy with synchronous implant Extent Subtotal false Inferred relationship Some
Bilateral nipple-sparing mastectomy with synchronous implant Method Implantation - action false Inferred relationship Some 2
Bilateral nipple-sparing mastectomy with synchronous implant Procedure site Both breasts false Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Royal Australasian College of Surgeons MALT surgical procedure reference set

Procedure foundation reference set

Back to Start