48526000: Ultrasound peripheral vascular flow study (procedure)


Status: current, Defined. Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
495120019 US scan of peripheral vessels en Synonym Active Case sensitive SNOMED CT core
786104011 Ultrasound peripheral vascular flow study (procedure) en Fully specified name Active Case insensitive SNOMED CT core
80851010 Ultrasound peripheral vascular flow study en Synonym Active Case insensitive SNOMED CT core
80853013 Doppler peripheral vascular flow study en Synonym Active Case sensitive SNOMED CT core
80854019 Echography of peripheral vascular system en Synonym Active Case insensitive SNOMED CT core
80855018 Ultrasonography of peripheral vascular system en Synonym Active Case insensitive SNOMED CT core


86 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Ultrasound peripheral vascular flow study Is a Doppler ultrasonography true Inferred relationship Some
Ultrasound peripheral vascular flow study Method Doppler ultrasound imaging - action true Inferred relationship Some 1
Ultrasound peripheral vascular flow study Method Ultrasound imaging - action false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Is a Diagnostic Doppler ultrasound false Inferred relationship Some
Ultrasound peripheral vascular flow study Is a Ultrasound procedure on cardiovascular system false Inferred relationship Some
Ultrasound peripheral vascular flow study Procedure site Structure of cardiovascular system false Inferred relationship Some 1
Ultrasound peripheral vascular flow study Method Evaluation - action false Inferred relationship Some 1
Ultrasound peripheral vascular flow study Procedure site - Direct Peripheral vascular system structure false Inferred relationship Some 1
Ultrasound peripheral vascular flow study Procedure site - Direct Blood vessel structure false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Method Ultrasound imaging - action false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Using device Doppler device false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Method Ultrasound imaging - action false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Has intent Diagnostic intent false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Procedure site - Direct Blood vessel structure false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Using device Doppler device false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Method Ultrasound imaging - action false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Procedure site - Direct Blood vessel structure false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Is a Procedure categorised by device involved false Inferred relationship Some
Ultrasound peripheral vascular flow study Is a Ultrasound procedure on cardiovascular system true Inferred relationship Some
Ultrasound peripheral vascular flow study Using device Doppler device false Inferred relationship Some 1
Ultrasound peripheral vascular flow study Method Ultrasound imaging - action false Inferred relationship Some 1
Ultrasound peripheral vascular flow study Procedure site - Direct Peripheral vascular system structure false Inferred relationship Some 1
Ultrasound peripheral vascular flow study Method Ultrasound imaging - action false Inferred relationship Some 1
Ultrasound peripheral vascular flow study Procedure site - Direct Peripheral vascular system structure true Inferred relationship Some 1
Ultrasound peripheral vascular flow study Using device Doppler device false Inferred relationship Some 1
Ultrasound peripheral vascular flow study Method Ultrasound imaging - action false Inferred relationship Some 1
Ultrasound peripheral vascular flow study Procedure site Peripheral vascular system structure false Inferred relationship Some 2
Ultrasound peripheral vascular flow study Method Measurement - action false Inferred relationship Some 1
Ultrasound peripheral vascular flow study Method Investigation - action false Inferred relationship Some
Ultrasound peripheral vascular flow study Procedure site Blood vessel structure false Inferred relationship Some
Ultrasound peripheral vascular flow study Has intent Diagnostic intent false Inferred relationship Some
Ultrasound peripheral vascular flow study Is a Doppler ultrasound false Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group
Ultrasound Doppler flow mapping of vein of upper limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Ultrasound peripheral vascular flow study, arterial and venous Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of artery of lower limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of vein of lower limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography of femoropopliteal artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography of iliac and femoral arteries Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of aorta and iliac artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Ultrasound Doppler flow mapping of artery of lower limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Ultrasound Doppler flow mapping of vein of lower limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of jugular vein Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Continuous wave Doppler analogue wave form analysis of upper limb arteries Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Duplex scan of upper limb arteries Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Duplex scan veins of upper limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography of artery of upper limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Ultrasound Doppler flow mapping of artery of upper limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of vein of upper limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography of carotid artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of superior mesenteric artery Is a True Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of aorta Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of abdominal and pelvic arteries Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Transcranial Doppler ultrasound of intracranial artery using microbubble contrast media for detection of emboli Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Transcranial Doppler ultrasound of intracranial artery for detection of emboli Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Complete Doppler ultrasonography of abdominal and pelvic arteries Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Transcranial Doppler ultrasound of intracranial artery with study of vasoreactivity Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of temporal artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography of inferior epigastric artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of superior epigastric artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of renal artery Is a True Ultrasound peripheral vascular flow study Inferred relationship Some
Ultrasound of lower limb vessels Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Ultrasound angiography of blood vessel of upper limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography of ophthalmic artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of iliac artery Is a True Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of vascular structure of limb Is a True Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography of venous structure of limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of penile artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of subclavian artery Is a True Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography of internal mammary artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography flow mapping of vein of right upper limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography flow mapping of vein of left upper limb Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of left carotid artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasound of right carotid artery Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography guided marking of skin over great saphenous vein Is a False Ultrasound peripheral vascular flow study Inferred relationship Some
Doppler ultrasonography guided marking of skin over small saphenous vein Is a False Ultrasound peripheral vascular flow study Inferred relationship Some

Reference Sets

Queensland allied health assessment reference set

Procedure foundation reference set

Imaging procedure reference set