FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

448841009: Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure)


Status: current, Defined. Date: 31-Jan 2019. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2898338012 Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Case insensitive SNOMED CT core
2902346016 Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance en Synonym Active Case insensitive SNOMED CT core


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Replacement of cardiac biventricular implantable cardioverter defibrillator true Inferred relationship Some
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Is a Replacement of cardiac defibrillator using fluoroscopic guidance true Inferred relationship Some
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Indirect Structure of heart true Inferred relationship Some 1
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Fluoroscopic imaging - action true Inferred relationship Some 2
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Direct device Implantable defibrillator true Inferred relationship Some 1
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Method Replacement - action true Inferred relationship Some 1
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Has intent Guidance intent true Inferred relationship Some 2
Replacement of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance Procedure site - Direct Structure of heart true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Royal Australasian College of Surgeons MALT surgical procedure reference set

Procedure foundation reference set

Imaging procedure reference set

Back to Start