446815007: Implantation of electrode into brain using stereotactic guidance (procedure)


Status: current, Defined. Date: 28-Feb 2022. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2879850011 Implantation of electrode into brain using stereotactic guidance (procedure) en Fully specified name Active Case insensitive SNOMED CT core
2883664014 Implantation of electrode into brain using stereotactic guidance en Synonym Active Case insensitive SNOMED CT core


1 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Implantation of electrode into brain using stereotactic guidance Method Implantation - action false Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance Method Insertion - action true Inferred relationship Some 441928801
Implantation of electrode into brain using stereotactic guidance Direct device Electrode true Inferred relationship Some 441928801
Implantation of electrode into brain using stereotactic guidance Using device Stereotactic device true Inferred relationship Some 441928801
Implantation of electrode into brain using stereotactic guidance Procedure site - Indirect Brain structure true Inferred relationship Some 441928801
Implantation of electrode into brain using stereotactic guidance Is a Insertion procedure true Inferred relationship Some
Implantation of electrode into brain using stereotactic guidance Direct device Electrode true Inferred relationship Some 1150963525
Implantation of electrode into brain using stereotactic guidance Procedure site - Indirect Brain structure true Inferred relationship Some 1150963525
Implantation of electrode into brain using stereotactic guidance Method Implantation - action true Inferred relationship Some 1150963525
Implantation of electrode into brain using stereotactic guidance Is a Procedure by intent true Inferred relationship Some
Implantation of electrode into brain using stereotactic guidance Using device Stereotactic device true Inferred relationship Some 2
Implantation of electrode into brain using stereotactic guidance Has intent Guidance intent true Inferred relationship Some 2
Implantation of electrode into brain using stereotactic guidance Procedure site - Direct Brain structure true Inferred relationship Some 2
Implantation of electrode into brain using stereotactic guidance Is a Implantation of electrode into brain true Inferred relationship Some
Implantation of electrode into brain using stereotactic guidance Method Insertion - action false Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance Direct device Electrode false Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance Procedure site - Indirect Brain structure false Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance Method Insertion - action false Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance Direct device Electrode false Inferred relationship Some 1
Implantation of electrode into brain using stereotactic guidance Procedure site - Indirect Brain structure false Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Stereotactic electroencephalogram Is a True Implantation of electrode into brain using stereotactic guidance Inferred relationship Some

Reference Sets

Royal Australasian College of Surgeons MALT surgical procedure reference set

Procedure foundation reference set

Description inactivation indicator reference set

REFERS TO concept association reference set