FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.8.2  |  FHIR Version n/a  User: [n/a]

446695008: Measurement of blood pressure at anterior tibial pulse using Doppler (procedure)


Status: current, Primitive. Date: 31-Jan 2011. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module
2879488016 Measurement of blood pressure at anterior tibial pulse using Doppler (procedure) en Fully specified name Active Initial character case insensitive SNOMED Clinical Terms Australian extension
2881532018 Anterior tibial Doppler pressure en Synonym Active Initial character case insensitive SNOMED Clinical Terms Australian extension
2881533011 Measurement of blood pressure at anterior tibial pulse using Doppler en Synonym Active Initial character case insensitive SNOMED Clinical Terms Australian extension


0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Measurement of blood pressure at anterior tibial pulse using Doppler Is a Examination of cardiovascular structure true Inferred relationship Some
Measurement of blood pressure at anterior tibial pulse using Doppler Is a Examination of lower limb true Inferred relationship Some
Measurement of blood pressure at anterior tibial pulse using Doppler Is a Procedure on lower leg true Inferred relationship Some
Measurement of blood pressure at anterior tibial pulse using Doppler Is a Procedure categorised by device involved false Inferred relationship Some
Measurement of blood pressure at anterior tibial pulse using Doppler Is a Procedure on blood vessel of lower limb true Inferred relationship Some
Measurement of blood pressure at anterior tibial pulse using Doppler Is a Procedure on artery of abdomen false Inferred relationship Some
Measurement of blood pressure at anterior tibial pulse using Doppler Is a Examination of abdomen false Inferred relationship Some
Measurement of blood pressure at anterior tibial pulse using Doppler Is a Procedure on pelvis false Inferred relationship Some
Measurement of blood pressure at anterior tibial pulse using Doppler Is a Blood pressure taking true Inferred relationship Some
Measurement of blood pressure at anterior tibial pulse using Doppler Procedure site - Direct Structure of anterior tibial artery false Inferred relationship Some 1
Measurement of blood pressure at anterior tibial pulse using Doppler Method Examination - action false Inferred relationship Some 1
Measurement of blood pressure at anterior tibial pulse using Doppler Using device Doppler device false Inferred relationship Some 1
Measurement of blood pressure at anterior tibial pulse using Doppler Method Examination - action true Inferred relationship Some 1
Measurement of blood pressure at anterior tibial pulse using Doppler Using device Doppler device true Inferred relationship Some 1
Measurement of blood pressure at anterior tibial pulse using Doppler Procedure site - Direct Structure of anterior tibial artery true Inferred relationship Some 1
Measurement of blood pressure at anterior tibial pulse using Doppler Is a Procedure on artery true Inferred relationship Some

Inbound Relationships Type Active Source Characteristic Refinability Group

Reference Sets

Procedure foundation reference set

Description inactivation indicator reference set

Back to Start