Status: current, Primitive. Date: 31-Jan 2002. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module |
3308451000168111 | Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | en | Synonym | Active | Case insensitive | SNOMED Clinical Terms Australian extension |
3308461000168113 | CRIF (closed reduction and internal fixation) of intracapsular fracture of neck of femur using a dynamic hip screw | en | Synonym | Active | Case sensitive | SNOMED Clinical Terms Australian extension |
457218015 | Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw | en | Synonym | Active | Case insensitive | SNOMED CT core |
710100015 | Closed reduction of intracapsular fracture of neck of femur and internal fixation using a dynamic hip screw (procedure) | en | Fully specified name | Active | Case insensitive | SNOMED CT core |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Method | Implantation - action | false | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Access | Open approach | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Procedure site | Structure of neck of femur | false | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Method | Fixation - action | true | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Closed reduction of fracture of proximal femur with internal fixation | true | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Operative procedure on hip | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Operation on trunk | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Hip joint implantation | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Thigh implantation | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Procedure on femur | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Reduction of fracture | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Method | Reduction - action | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Direct morphology | Fracture | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Procedure on hip joint | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Open reduction of fracture with internal fixation | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Direct device | Orthopaedic internal fixation system | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Open reduction of fracture with fixation | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Using | Orthopaedic internal fixation system | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Reduction procedure | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Open reduction with internal fixation | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Procedure site - Indirect | Bone structure | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Direct device | Orthopaedic internal fixation system | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Open reduction | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Procedure site - Direct | Structure of neck of femur | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Using device | Orthopaedic internal fixation system | false | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Procedure site - Direct | Bone structure | false | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Using device | Bone screw | true | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Direct morphology | Fracture | false | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Direct morphology | Fracture | false | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Fixation of hip | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Closed reduction of fracture of femur with internal fixation | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Closed reduction of fracture of hip | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Fixation of fracture using screws | true | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Method | Closed reduction - action | true | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Direct morphology | Fracture | true | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Direct morphology | Fracture | true | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Procedure site - Direct | Structure of neck of femur | true | Inferred relationship | Some | 1 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Procedure site - Direct | Structure of neck of femur | true | Inferred relationship | Some | 2 | |
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Operative procedure on pelvis | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Fixation of fracture using dynamic compression system | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Operation on hip joint | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Is a | Procedure on thigh | false | Inferred relationship | Some | ||
Closed reduction of intracapsular fracture of neck of femur with internal fixation using a dynamic hip screw | Procedure site | Bone structure | false | Inferred relationship | Some | 1 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
Reference Sets
Royal Australasian College of Surgeons MALT surgical procedure reference set
Procedure foundation reference set